709 Alignment System
File Output
Validate
124
Save Text As Pressing this button causes the 709 Alignment Software to write the data to a tab-
delimited text file. This text file can be opened in Microsoft Excel and analyzed
as desired and formatted for various reports.
The text file also includes:
Validation Status, which states by what amount (largest difference) that the
data passes or fails, for example: Maximum Bending Passes Class 5 Criteria
by 12.50 µe.
Chart X-Axis, which is Strain Gauges or Analog Input depending on the
global settings option.
Target Limit, which is Strain Trough or Percent Level depending on the
global settings option.