Mts Multipurpose Elite Manual de usuario

Busca en linea o descarga Manual de usuario para Hardware Mts Multipurpose Elite. MTS Multipurpose Elite User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 662
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
MTS TestSuite
Multipurpose Elite User Guide
100-209-349 K be certain.
Vista de pagina 0
1 2 3 4 5 6 ... 661 662

Indice de contenidos

Pagina 1 - MTS TestSuite

MTS TestSuiteMultipurpose Elite User Guide100-209-349 K be certain.

Pagina 2

TestCreationDate...222TestCreationTime.

Pagina 3 - Table of Contents

• You can use one from a previous run of the same test.• You can import a test run (and its specimen definitions) from one that was exported from anot

Pagina 4 - User and Role Management

Saving Tests OverviewThe application saves test changes in two ways:• User-prompted saves• Automatic saves (background saves)User-prompted savesWhen y

Pagina 5 - Working with Resources

2. To close the test, select File > Close Test .3. You are prompted to save the test if you have made changes to the test.For More InformationConce

Pagina 6

• A copy of the variable definitions at the time the test run is created• Variable values during the test run• Runtime progress (state) information• R

Pagina 7

Multiple instances of test runsTo avoid possible resource conflicts, do not open multiple instances of the same test run.For More InformationTaskCreat

Pagina 8

An error indicator is shown next to any incorrect values. If you change a value, the change is validatedafter you click outside the cell.4. Click Yes

Pagina 9

Note:Although a template can include test resources, if the template is designed for a particularcontroller configuration, the resources may not map t

Pagina 10

For More InformationConceptTemplates Overview (p. 105)ReferenceDelete a Template (p. 107)Delete a TemplateAccessC:\MTS TestSuite\TemplatesYou must use

Pagina 11

MTS TestSuite foldersMTS TestSuite Folder ManagementFrom WindowsExplorerFrom TestSuiteApplicationFolderExtensionFile typeNo file manipulationallowed e

Pagina 12

From Windows ExplorerFrom TestSuiteApplicationFile ExtensionFile type(such as, ReportTemplates).Copy, move, paste,delete, renameImport/export.tsprojEx

Pagina 13 - Working with Specimens

YpeStartIndex...245Math Functions.

Pagina 14 - Test Activities

a) Make sure that the new directory is empty.b) Move the tests to the new directory.Note:When using the Windows XP OS, each test appears as a Test fol

Pagina 15

• Test Runs• SpecimensThe names you specify are assigned to the items when you first create them. You can change the nameat any time.For More Informat

Pagina 16

For More InformationConceptProjects Overview (p. 110)TaskExport and ImportTest Information Export OverviewWhen you export a test, MTS TestSuite combin

Pagina 17

• Test resources• Test runs from MTS Fatigue and Fracture (FnF) applicationsTest resources importClick the Import Resources button in the Resources wi

Pagina 18

1. Open the test with the test runs that you want to export.2. Select File > Export > Test Run.3. In the Export Test Run window, expand the expo

Pagina 19 - Test-Run Displays

7. Select Save in the Specimen Geometry Export window. The application writes the selected items fromthe source project to the export file.8. Click OK

Pagina 20

a) Click Import resources from another test to overwrite the test resources with the importedresources.b) In the Import resources from another test wi

Pagina 21 - Running Tests

ConceptSpecimen Geometry Manager Overview (p. 307)Update All Overview (p. 310)TaskUpdate All Geometry-Specific Functions (p. 311)Compatible Specimen G

Pagina 22 - Appendix: Trend Monitoring

Create Diagnostic File WindowCreate Diagnostic File Window PropertiesDescriptionPropertyRequired. Browse to the location where youwant to save the dia

Pagina 23 - Technical Support

ConceptDiagnostic Files Overview (p. 117)TaskCreate a Diagnostic File (p. 119)Create a Diagnostic FileA test must be open to create a diagnostic file.

Pagina 24

truncate...258XIntercept

Pagina 25 - If You Contact MTS by Phone

Logging LevelsThe Application Log warnings and errors pertain to loading or running the test. The following informationcan be displayed:• Errors—These

Pagina 26

• From Existing File—Opens a Windows Explorer window so that you can show a log (.log) file from aprevious test session.Sorting log informationTo sort

Pagina 27 - Documentation Conventions

If you double-click an item in the Error list, the view changes to show the location of the error. Error andwarning icons are placed on or near the pr

Pagina 28 - Caution:

Removing a Meter1. Click the Meters tab.2. Right-click the meter you want to remove.3. Select Remove.Configuring MetersAfter you add a meter to the Me

Pagina 29

valley. When adjusting the sensitivity, keep in mind that setting the sensitivity too low may cause signalnoise to be recognized as peaks and valleys,

Pagina 30

Conversions from Earlier VersionsConversion Wizard OverviewThe Conversion Wizard utility converts user-created test and template files from one applic

Pagina 31 - Multipurpose Elite Overview

Convert a Test or TemplateTo convert a test or template:1. Open or import your test. The Conversion Wizard window welcomes you to the Conversion Wizar

Pagina 32 - Introduction

• JIC• KIC• LCFLegacy filesLegacy files have a similar naming convention. File names are not case-sensitive: <name><datatype>.<extensio

Pagina 33

Import Legacy Data PropertiesImport Legacy Data PropertiesDescriptionItemShow the name of the Legacy template for the testtype, such as Legacy FCG.Tem

Pagina 34

Note:If you cannot see the Edit button, check your screen resolution. It may not be visible if your screenresolution is less than 1280 x 1024. (Start

Pagina 35 - Test Definition

Edit Python Functions...282Create V

Pagina 36 - Test Run

Edit General SettingsNote:If you cannot see the Edit button, check your screen resolution. The Edit control may not be visibleif your screen resolutio

Pagina 37 - MTS TestSuite

Command Settings TabQuick access:Explorer panel > Test Name > Test Definition > Command Settings tabAccess Command Settings TabTo access the

Pagina 38 - User Interface

Taper and ramp settingsYou set the taper times and ramp times in the Station Manager application. These settings are saved inthe station configuration

Pagina 39

Note:Power status applies only to control channels. If a procedure does not contain control channels, thepower status has no effect on the procedure.P

Pagina 40 - General Conventions

and automatically boosts subsequent commands to ensure that the LVDT feedback achieves the desiredcommand. You can view the compensated command with t

Pagina 41 - Naming Conventions

For More InformationConceptCompensator Overview (p. 133)TaskSet Up and Use a CompensatorFor information about compensators, see the “Channel Compensat

Pagina 43 - Filter Data

Data Acquisition (DAQ)Topics:•Data Acquisition Overview...

Pagina 44 - Docking and Undocking Panels

Data Acquisition OverviewData Acquisition (DAQ) activities accumulate user-defined data during portions of the test. The acquireddata can be:• Saved t

Pagina 45 - Docking a Panel

Data Acquisition Activity ProcessMTS TestSuite | 139Data Acquisition (DAQ)

Pagina 47 - Licenses

Comparison of DAQ Activity SettingsHigh-SpeedDAQ (MPEonly)Max/MinDAQCycle + DAQCustom Waveform +DAQDAQDwell + DAQ+ Detection(TWE)GoTo + DAQ+ Detection

Pagina 48 - License Utility Overview

High-SpeedDAQ (MPEonly)Max/MinDAQCycle + DAQCustom Waveform +DAQDAQDwell + DAQ+ Detection(TWE)GoTo + DAQ+ Detection(TWE)PropertiesAvailableAvailableHa

Pagina 49

High-SpeedDAQ (MPEonly)Max/MinDAQCycle + DAQCustom Waveform +DAQDAQDwell + DAQ+ Detection(TWE)GoTo + DAQ+ Detection(TWE)PropertiesN/AAvailableAvailabl

Pagina 50

Signal listEach DAQ activity includes a Signal list where you can select the signals that you want to acquire. Whenany of the triggers defined in the

Pagina 51 - Remove a License

TaskReferenceTimed DAQ Trigger Properties (p. 144)Peak Valley DAQ Trigger Properties (p. 147)Timed DAQ Triggering OverviewTimed data acquisition recor

Pagina 52 - Version Information Overview

• Sample rate - (Default) Specify the frequency at which data is acquired. For example, with a samplerate of 1 Hz, the buffer acquires data points onc

Pagina 53

Delta Level Triggering ExampleWhen a value outside of the delta value is detected, the trigger establishes a new reference level andmonitors the refer

Pagina 54 - Managing Users

Peak-Valley Triggering ExampleFor More InformationTaskReferenceTimed DAQ Trigger Properties (p. 144)Peak Valley DAQ Trigger Properties (p. 147)Peak Va

Pagina 55

TaskConfigure Data Acquisition (DAQ) BuffersData Acquisition (DAQ) Buffers OverviewEach DAQ activity has its own buffer that is used to move the user-

Pagina 56

Typically, set the buffer size so that there are one to five buffers per second. You can set the buffer sizebetween 1 and 16,000 data samples.Note:Whe

Pagina 57

Ramp Activity Properties...350Sweep...

Pagina 58

Note:Make the buffer size large enough to store the data for the event that you want to capture.For More InformationTaskConfiguring the Buffer Type (p

Pagina 59 - Managing Roles

Point-by-Point Data Processing DiagramWhen the data is put into variables, it is appended one data point at a time, and any Additional VariableCalcula

Pagina 60 - Create a Custom User Role

Block Data Processing DiagramFor More InformationTaskReferenceBlock or Cycle Decimation Filter Settings (p. 152)Block or Cycle Decimation Filter Setti

Pagina 61 - Default Roles

Block Decimation Filter Selection WindowBlock/Cycle Decimation Filter SettingsDescriptionSettingSpecify the increments at which cycles are stored per

Pagina 62

DescriptionSettingUpdate Interval Note:Applicable to cycle decimation for test-run displays only.The speed at which data can be shown. This is useful

Pagina 63

• Using variables to define activity properties.Save Data to Variables DiagramFor More InformationTaskAutomatically Mapping Variables (p. 161)Manually

Pagina 64 - View Users Assigned to a Role

Data Acquisition WindowSignal-to-Variable Mapping OptionsDescriptionSettingThe signal data is not saved to variables.NoThe acquired signals are automa

Pagina 65 - Remove a Custom User Role

DescriptionSettingthe automatic settings and allows you to finish any mapping that theautomatic setting did not map.This selection allows you to manua

Pagina 66 - Privileges

Note:If you select Yes, automatically map variables, the Map Variables window opens in read-onlymode.Map Variables WindowMap Variables Window Properti

Pagina 67

DescriptionPropertyNo.Important:If there are multiple DAQ activities in a test workflow,the Before starting setting for the first DAQ activityshould b

Pagina 68

Cycle Change Detection Activity Properties...397Digital Input...

Pagina 69 - MTS TestSuite

DescriptionPropertyNo.• If the data is being processed block-by-block, all dependentcalculations are added.To edit one of the Additional Variable Calc

Pagina 70 - Configuration Window

Automatically Mapping VariablesImportant:To simplify the mapping of variables, you can initially select Yes, automatically map variables tomap the maj

Pagina 71

• Use Default Variable button—In the Signal to Variable Mapping table, select a signal and click theUse Default Variable button to automatically map t

Pagina 72 - Project Management

Working with VariablesTopics:•Variable Basics...

Pagina 73 - Project Tab

Variable BasicsVariables OverviewA variable is a name associated with a data value. A variable stores one or more values and provides theability to st

Pagina 74

DescriptionItemData acquisition activities can be configured to store signal data invariables. This process, called variable mapping, makes this data

Pagina 75 - Audit Trail

DescriptionItemtheir current values is shown. The operator can edit the variable valuesas required.Note:Variables used with this activity must have th

Pagina 76 - E-Mail Overview

• CalculatedThe desired use of the variable dictates the variable type (or combination of types) defined in the propertysettings for a variable. Other

Pagina 77 - E-Mail Settings

Text Variables OverviewTo specify that a variable hold a string, select Text or Array of Text as the Type. In addition to using textvariables to store

Pagina 78

a[0], a[1], a[2], a[3], a[4], a[5], a[6], a[7], a[8], a[9]In the preceding example, a[4] refers to the fifth element of the array a.An array variable

Pagina 79

Set Span and Setpoint Activity Overview...424Segment Generator Diagram...

Pagina 80 - Units Management

An index variable typically defines an Index (data point) value in an array variable – not an actual signalvalue (that is, load value). On the left si

Pagina 81 - Predefined Unit Sets

5. In the Properties panel for the Assign Variables activity, click the green + sign to add the variable tothe activity.6. Select the variable on the

Pagina 82 - Unit Set Manager Overview

Boolean Variable PropertiesNote:To specify that a Boolean variable hold a multiple-value array, select Array of Boolean as the Type.Boolean variables

Pagina 83 - Unit Set Manager Properties

Note:If a calculation has been defined for the variable and you clear the Is Calculated check box, thepanel clears and the equation is lost. If you la

Pagina 84 - Add a Custom Unit Set

DescriptionItemNumberVariable Actions MenuSelects which columns you want to show in the variables table.Column Chooser2Column ChooserFilters by your s

Pagina 85 - Remote Server Settings

Setting Variable Order Overview (p. 178)TaskSelecting Columns Shown in the Variables Table (p. 175)Showing and Hiding Disabled Variables (p. 176)Showi

Pagina 86

For More InformationConceptViewing Variable Usage (p. 177)Setting Variable Order Overview (p. 178)ReferenceVariables Editor (p. 173)Showing and Hiding

Pagina 87

Viewing Variable UsageAccessDefine tab > Variables tabThe Used By column in the Variables table indicates if and where a variable is used in the ap

Pagina 88 - Resources Overview

Setting Variable Order (p. 179)Delete a Variable (p. 179)ReferenceVariables Editor (p. 173)Setting Variable Order OverviewYou can set the order of Pre

Pagina 89 - Resources Tab

Setting Variable OrderNote:The order defined here sets the order in which the variables appear in the Setup Variables window(Pretest) or the Results t

Pagina 90

Wait for Operator Action...456Wait for

Pagina 91

Variable CategoriesDefault variable categories include System variables, Specimen variables, and Variables (the defaultcategory for user-defined varia

Pagina 92 - Resources Tab Buttons

Create a Variable Category for Selected Variables (p. 182)Rename a Variable Category (p. 182)ReferenceSpecimen Variables CategoryImportant:To view Spe

Pagina 93 - Add Test Resources

2. Click the Add New Variable icon (+) and enter a new variable identifier.3. In the Properties panel, click <New Category> in the Category list

Pagina 94

2. Select a variable in the list. The properties for the selected variable appear in the Properties panel.Editing Properties for Multiple VariablesYou

Pagina 95

DescriptionItemcharacters. The name cannot begin with a numberand must begin with an alphabetical character. Theycannot contain spaces, periods, or ot

Pagina 96

DescriptionItem• Boolean—The variable type holds a Booleanvalue of either True or False.• Number—(Default) The variable type holdsnumeric values.• Tex

Pagina 97 - MTS TestSuite

DescriptionItem• Use Previous Test Run ValueVariable Calculation PropertiesThe Calculation panel in the variables Properties panel shows the defined c

Pagina 98 - Tests Overview

Availability WindowVariable Availability PropertiesDescriptionItemSpecify variable values from the Setup Variableswindow prior to test initialization.

Pagina 99

Format PropertiesFormat PanelUse the Format panel on the Properties panel to format the display of a numeric variable value.Variable InformationDescri

Pagina 100 - Creating Tests Overview

Range PanelVariable Range PropertiesDescriptionItemWhen this option is selected, the application checksthe value of the variable during the test to de

Pagina 101 - Save a Test

Write Variables to File Activity Properties...480Conguring the Write Variables

Pagina 102 - Test Runs

DescriptionItemFor example, if a value of -5 is entered and the rangeis Minimum 0 Exclusive, Maximum 10 Exclusive, andthe Resolution is 1, the value w

Pagina 103

Creating Variables OverviewYou can create and define variables in the Define tab > Variables tab. The MTS TestSuite applicationsalso provide shortc

Pagina 104 - Create a New Test Run

Toggle Button for Property Value3. Open the list and click <new variable>. You can also select an existing variable for the property value.New V

Pagina 105 - Templates

Creating a Text VariableTo create a text variable:1. Navigate to the Define tab > Variables tab.2. Click the Add New Variable (+) icon.3. Enter a V

Pagina 106 - Create a Template

Creating Array VariablesYou can create array variables from the following locations:• Click the add new variable (+) icon in the Define tab > Varia

Pagina 107 - Manage MTS TestSuite Files

Example 2You can create a wave shape variable with values of triangle, sine, and square as its values as anotherexample.Global and local choice listsY

Pagina 108 - *Project Directory Files

For More InformationConceptVariable Choice Lists Overview (p. 194)ReferenceDefine Global Choice List Window (p. 196)Editing a Global Choice ListYou ca

Pagina 109

Define Global Choice List WindowDefine Global Choice List WindowDescriptionItemDisplays the Name of the global choice list. You canselect the name and

Pagina 110 - Assign Project Names

Editing a Global Choice List (p. 196)Removing a Global Choice List (p. 196)Adding a Local Choice List (p. 198)Adding a Local Choice ListFollow these s

Pagina 111 - Import Projects

3. In the Save data to variables? panel, select the Yes, automatically map variables or Yes, manuallymap variables option and click Configure.Note:If

Pagina 112 - Export and Import

©2014 MTS Systems Corporation. All rights reserved.Trademark InformationMTS is a registered trademark of MTS Systems Corporation within the United Sta

Pagina 113 - Exporting a Test Run

Variable Meter Properties...544Create a Variable Met

Pagina 114 - Export a Specimen Geometry

DescriptionPropertyNo.This setting is useful when multiple DAQ activities write datato the same array at different points in the test.Important:If the

Pagina 115 - Import Test Resources

DescriptionPropertyNo.• If the data is being processed in a point-by-point manner,only dependent array calculations are included.• If the data is bein

Pagina 116 - Selecting a Domain

Map Signals to a VariableVariable Mapping OverviewCycle, point-by-point, and group data acquisition activities require you to map variables to the sig

Pagina 117 - Creating Diagnostic Files

User variable mappingAlternatively, you can map a user-defined variable to any signal data calculation. The variable you mapmust have a dimension that

Pagina 118

• Group data is stored at each boundary, such as a step or segment.• Noncyclic data is stored at the end of the data acquisition. The stored data lets

Pagina 119 - Application Log Overview

Note:Calculations are validated only on syntax and references to variables and functions, not expectedresults.Variables panelThe Variables panel of th

Pagina 120

DirectionFunctionOperatorPrecedenceFunction Call( )Variable-SpecificInformation.Right-to-LeftLogical NOT!2Left-to-RightUnary Plus+Unary Minus-Ones Com

Pagina 121 - Error Identification

DirectionFunctionOperatorPrecedenceLeft-to-RightLogical OR||12Right-to-LeftAssignment=13Left-to-RightComma - List Separator,14Variable-Specific Inform

Pagina 122 - Resetting a Meter

• Signal or test inputIn all cases, the argument type that is shown in the Calculation window must be replaced by a meaningfulvalue. The meaningful va

Pagina 123 - Configuring Meters

Expanded ChannelValue FunctionModulus Calculation FunctionsModulus is calculated from the slope of the Least Squares Fit calculation of the Stress and

Pagina 124 - Meter Types

Add a Label to a Test-Run Display...595Test Procedure...

Pagina 125 - Convert a Project

3. Expand the nominal end index away from the start index until the new modulus value differs from thenominal modulus by more than 2%.4. The endIndex

Pagina 126 - Legacy Project Import

Calculation Editor WindowParts of the Calculation Editor WindowDescriptionItemNumberUse the Calculation panel to build a variable calculation. Youcan

Pagina 127

DescriptionItemNumberinterpreted as a single variable name. This is likely toresult in a “...variable..., was not found” error message.The Errors pane

Pagina 128 - General Settings

DescriptionItemNumberNote:The variable parameters between the parentheses arenot the identities of the variables. They indicate the typeof variable th

Pagina 129 - General Settings Properties

TaskReferenceCalculation Editor (p. 210)Notation for Referencing VariablesYou can reference variables with delimited notation. A dot separates the var

Pagina 130 - Edit General Settings

However, some operators like the Not (!), Ones Complement (~), and Subtraction when used as a Negate(-), operate on only one argument to the right.Fun

Pagina 131 - Command Settings Tab

• A string value must be enclosed between double-quotes. For example: the function ToLower(string),can be replaced by ToLower(“This is a short sentenc

Pagina 132

SyntaxNewArray(Size, DefaultValue)ParametersSize - The size of the new array.DefaultValue - The default value that will populate every index within th

Pagina 133 - Compensator Overview

ParametersForceArray - The force array data.ComplianceCoefficients - The coefficient array generated during the compliance Test Run.Unit ClassExtensio

Pagina 134 - Compensator Availability

SyntaxPolynomial(X,Coefficients)Unit ClassThe units associated with the Y data used to calculated the coefficients.ExamplePolynomial(X, coefficients)T

Pagina 135 - Set Up and Use a Compensator

Exporting Raw Data...627Appendix

Pagina 136

Note:The TimePattern depends upon your Windows settings in the Format tab for regional areas.GetTransitionTimeReturnsReturns the time from the specifi

Pagina 137 - Data Acquisition (DAQ)

SyntaxSignalFullScale(SignalName)ParametersSignalNameSystemRateReturnsThe maximum data rate for the controller.SyntaxSystemRate()TraceReturnsGets the

Pagina 138 - Data Acquisition Setup

SyntaxBlock[blockName, Index].variableParametersblockNameCycleReturnsAccesses the variable in cycles.SyntaxCycle[Index].variableTestRunReturnsAccesses

Pagina 139 - MTS TestSuite

ExamplesTestCreationDate([ “d”])Returns a test creation date in a short date format, assuming a United States English culture:4/15/2012TestCreationDat

Pagina 140

ParametersdatePattern—Formats the date according to the specified pattern. For example, “d” is a short date pattern(MM/dd/yyyy); “D” is a long date pa

Pagina 141

TestRunCreationDateNote:This function replaces the SampleCreationDate function from the TW4 application.ReturnsReturns the creation date of the test r

Pagina 142 - Select Signals

ParameterstimePattern—Formats the time according to the specified pattern. Set the time pattern to the exact formatdesired. For example, to obtain the

Pagina 143

CurrentTestRunDirectoryReturnsReturns the current test run directory. The directory is set in Preferences > Configuration > Project.SyntaxCurren

Pagina 144 - Timed DAQ Triggering Overview

Unit ClassStringTestDirectoryReturnsReturns the directory for the test. The directory is set in Preferences > Configuration > Project.SyntaxTest

Pagina 145

SyntaxHysteresisArea(StressArray, StrainArray)ParametersStressArrayStrainArrayMeasInelasticStrainMaxMeasured Inelastic Strain Maximum. The measured in

Pagina 146

Technical SupportHow to Get Technical SupportStart with your manualsThe manuals supplied by MTS provide most of the information you need to use and ma

Pagina 147

The StrainA function returns the value:((StrainMax - StrainMin)/(StrainMax + StrainMin))StrainRStrainR(StrainMax, StrainMin)The StrainR function retur

Pagina 148 - Linear Buffers

Starting Point of RegionTo determine the starting point of the analysis region, the algorithm will select the first point where the “minload” value is

Pagina 149 - Circular Buffers

This formula:1. Searches the _Load channel.2. Looks for the _Load channel to drop 80% from its peak value. 80% is the value of the input BreakDrop.If

Pagina 150 - Configuring the Buffer Type

1. Searches the _Load channel and the PrimaryExtension channel.2. Looks for the _Load channel to drop 80% from its peak value, and for the PrimaryExt

Pagina 151 - Block Data Processing

ReturnsThe fracture index is where this line intersects the curve (Type I) or where it intersects a peak if it comesbefore this point (Type II or Type

Pagina 152

LowerYieldIndexThis LowerYieldIndex function is used to calculate the first occurrence of a zero slope after the upper yieldpoint.1. The search for th

Pagina 153

Parametersy-channel - This argument is the channel that represents the Y-axis for the Least Squares fit. The unitsfor this channel are normally in For

Pagina 154

Parametersy-channel - This argument is the channel that represents the Y-axis for the Least Squares fit. The unitsfor this channel are normally in For

Pagina 155

Parametersy-channel - This argument is the channel that represents the Y-axis for the Least Squares fit. The unitsfor this channel are normally in For

Pagina 156

Parametersy-channel - This argument is the channel that represents the Y-axis for the Least Squares fit. The unitsfor this channel are normally in For

Pagina 157 - Map Variables Window

When you have more than one MTS system, the system job number identifies your system. You can findyour job number in your order paperwork.Example syst

Pagina 158

Offset - The offset from the modulus line to use in the calculation.EndIndex - An optional end index that is used to limit the search region. If this

Pagina 159

EndIndex - The optional end index of the region. If this parameter is missing, the end is associated withthe end of the array data.Tolerance - The per

Pagina 160

YieldIndexByZeroSlopeThe YieldIndexByZeroSlope function determines the yield index by searching the curve in segments untilthe angle of the curve decr

Pagina 161 - Manually Mapping Variables

ReturnsThe function returns the index associated with the end of the Yield Point Elongation region.SyntaxYpeEndIndexByIncreasingLoad(ForceArray, YPESt

Pagina 162 - Save Data to File (Optional)

ParametersForceArray - The force array used to determine end of the Yield Point Elongation region.DisplacementArray - The displacement array used to d

Pagina 163 - Working with Variables

Note:This value can never be lower than the zero slope index.Zero Slope IndexYPE End IndexYpeStartIndexThe YpeStartIndex function finds the start of t

Pagina 164 - Variable Basics

ReturnsThe function returns the index associated with the start of the Yield Point Elongation region.SyntaxYpeStartIndex(ForceArray, DisplacementArray

Pagina 165 - Setting Variable Values

Important:This function is only used for integer numbers.Syntaxabs(number)acos (Arc Cosine)Syntaxacos(number)This function is used to calculate the ar

Pagina 166 - Variable Types Overview

avgSyntax:avg(number1, number2,[numberN])Returns the average of a series of numbers.CeilingThis function is used to round the specified number up to t

Pagina 167 - Numeric Variables Overview

ExampleChannelValue(Extension, Load, PeakLoad)This example returns the Extension value associated with the PeakLoad value located in the Load array.co

Pagina 168 - Array Variables Overview

— Messaging applicationsIf You Contact MTS by PhoneA Call Center agent registers your call before connecting you with a technical support specialist.

Pagina 169 - Array Variable Uses

Example 1CurveArea (_Load, SlackExt, 0 , SizeOfArray(_Load)-1)This formula calculates the area under the entire Load versus Extension curve.Example 2C

Pagina 170

Note:Unlike plastic strain, there is no flag to set whether the specified load point should be found afterthe peak or before. This is because the Elas

Pagina 171 - Boolean Variables Overview

ExpThis function is used to calculate the value of e (2.71828...) raised to the power specified by the exponent.Syntaxexp(number)ReturnsA value “e” ra

Pagina 172 - Calculated Variables Overview

IsInvalidNumberSyntaxIsInvalidNumber(number)Checks the validity of the supplied value.ReturnsThis function returns 1 if the value being tested is inva

Pagina 173 - Variables Editor

UnitsY-Axis unit / X-Axis UnitExampleLeastSquaresFit(Force, Extension, Slope1, Slope2)This formula returns the slope of the line between the two index

Pagina 174

minThe minimum of a series of numbers.Syntaxmin(number1, number2[, numberN])MinDouble()Returns the minimum value for the type of number.SyntaxMinDoubl

Pagina 175

ParametersForceArray – The array containing force data.StrainArray – The array containing Strain data.StartIndex – The start index of the modulus regi

Pagina 176

Syntaxpow(base, exponent)Example 1Pow(2, 3)This formula returns the value 8 (2^3, or 2*2*2)Example 2Pow(5, 2)This formula returns the value 25 (5^2, o

Pagina 177 - Viewing Variable Usage

sin(number)ReturnsSine of the specified angle.Syntaxsin(number)sinh(number)Hyperbolic sine of the specified number.Syntaxsinh(number)sqrt(number)The s

Pagina 178

Parameternumber – The number to be truncated.Unit ClassSame the number.Exampletruncate(4.5) = 4XInterceptValueThe XInterceptValue function returns X-I

Pagina 179 - Delete a Variable

• Write down any specific instructions.After you callMTS logs and tracks all calls to ensure that you receive assistance for your problem or request.

Pagina 180 - Variable Categories

XInterceptValueYInterceptValueThe YInterceptValue returns the point where the line determined by the index values crosses the Y-Axis.ReturnsThe index

Pagina 181 - Specimen Variables Category

YInterceptValueOperator FunctionsThis section describes Operator functions and precedence.Operators and PrecedenceThe following table shows all the re

Pagina 182 - Viewing Variable Properties

DirectionFunctionOperatorPrecedenceVariable-SpecificInformation.Right-to-LeftLogical NOT!2Left-to-RightUnary Plus+Unary Minus-Ones Complement~Left-to-

Pagina 183 - Variable Properties Reference

DirectionFunctionOperatorPrecedenceRight-to-LeftAssignment=13Left-to-RightComma - List Separator,14ChooseReturnsReturns a value based on the evaluatio

Pagina 184

ParametersVarArray - The data array to be analyzed.PeakCriterion - A percentage of the peak magnitude used to detect when peaks occur.NumberOfPeaks -

Pagina 185

Unit ClassSame as the array data.ExampleAveragePeaks(_Load, LoadPeakCriteria, 0, SizeOfArray(_Load)-1)This formula:1. Searches the _Load channel.2. Lo

Pagina 186

ReturnsThe average array value.SyntaxAverageValue(VarArray, startIndex, endIndex)ParametersVarArray - The variable being analyzed.StartIndex - The sta

Pagina 187

2. Checks to see if the value of the Strain channel has exceeded the value of the RemovalPoint input.3. Reports the value of the Extension channel whe

Pagina 188 - Format Properties

endIndex - The optional end index of the region. The search ends at the last data point if this parameteris missing.Threshold - The optional threshold

Pagina 189

3. Searches between the peak load's point and the last data point.4. Finds the next peak and returns its array index.5. Only calculates the resul

Pagina 190 - Choice List Panel Properties

PrefaceBefore You BeginSafety first!Before you use your MTS product or system, read and understand the safety information provided withyour system. Im

Pagina 191 - Creating Variables Overview

SyntaxNumberOfPeaks(VarArray, peakCriterion[, startIndex, endIndex, threshold])ParametersVarArray - The array data being analyzed for peaks.peakCriter

Pagina 192 - Creating a Numeric Variable

This formula calculates the standard deviation between given by the variables Slope1 and Slope2.TearIndexLocates the index of the tear value in an arr

Pagina 193 - Creating a Boolean Variable

CalibrationDueDateReturnsReturns the calibration due date of the sensor attached to a signal.SyntaxCalibrationDueDate(SignalName)ParameterSignal Name—

Pagina 194 - Creating Array Variables

SyntaxSerialNumber(SignalName)ParameterSignal Name—The “SignalName” in signal functions is the internal name of the signal and must be quotedor passed

Pagina 195 - Defining a Global Choice List

ParametersubstringstringstartIndexUnit ClassStringleftReturnsExtracts a substring from the left side of a string.Syntaxleft(string, length)Parameterss

Pagina 196 - Removing a Global Choice List

NumberToStringReturnsCreates a string from the specified number with the optionally specified digits.SyntaxNumberToString(number[, digits])Parametersn

Pagina 197

Unit ClassStringStringToIntegerReturnsConverts a string to an integer number.SyntaxStringToIntger(string)ParametersstringUnit ClassStringStringToNumbe

Pagina 198 - Advanced Variable Information

Unit ClassStringtoupperReturnsConverts a string to all uppercase.Syntaxtoupper(string)ParametersstringUnit ClassStringTrimStringEndReturnsRemoves whit

Pagina 199

Unit ClassStringvarIdentifier.DisplayValueThis construct is implicit in the MTS TestSuite application. Use this syntax in a calculation to return a st

Pagina 200

Functions Tab PropertiesDescriptionItemDisplays the function name. The name cannot containspaces, begin with a number, or contain specialcharacters.Fu

Pagina 201

Warning:Warning notices indicate the presence of a hazard with a medium level of risk which, if ignored,can result in death, severe personal injury, o

Pagina 202 - Map Signals to a Variable

• Enter If statements, Loop statements, and other statements as supported in Python for more complexcalculations.• Assign multiple variables to a func

Pagina 203 - Save Variables

Edit Function Window PropertiesDescriptionItemShows the function name. A name that is uniquewithin the test is prefilled in the Function Name field.Fu

Pagina 204 - Variables Calculations

The above syntax is the function variable code to get the value of the array variable.Non-array variablesTo read a test variable that is not an array,

Pagina 205 - Operators and Precedence

For More InformationReferenceFunctions Tab (p. 278)Edit Function Window Overview (p. 279)Edit Function Window Properties (p. 280)Function Usage and Sy

Pagina 206

Python OverviewPython is an interpreted, general purpose, high-level programming language with an extensive resourcelibrary. You can use Python to ext

Pagina 207 - Variable-Specific Information

Import IronPython LibrariesTo import an IronPython library for use in a custom function, you must explicitly include the path to yourIronPython instal

Pagina 208

DescriptionExample (using variable num)MethodGet the value of NUM as textNUM.ValueToStringValueToStringText VariablesDescription of Text VariablesDesc

Pagina 209 - Modulus Calculation Functions

Array of TextDescription of Text ArraysDescriptionExample (using variable txtArray)MethodGet the number of values stored inTXTArrayTXTArray. LengthLen

Pagina 210 - Calculated Variable Functions

Define the custom functionNote:The MTS TestSuite custom function editor does NOT include Python libraries.• Import the resources you will be referenci

Pagina 211

# these variables, it is recommended that you simulate their# existence here by initializing them with some valid default# values.# ==================

Pagina 212

Electronic manual conventionsThis manual is available as an electronic document in the Portable Document File (PDF) format. It can beviewed on any com

Pagina 213

print "Failed to write array to " + str(file)# Clear tsVarArray to demonstrate readFileAsArraytsVarArray = []print "\ntsVarArray is now

Pagina 214

Compare ToolTestSuite Compare Tool OverviewAccessTool menu > Compare > Variable or FunctionCompare Variables or FunctionsThe Compare tool shows

Pagina 215

Note:The Count column shows the number of variables or functions in each selected item.3. Repeat until you have selected what you want to compare.4. C

Pagina 216 - Array Functions

Working with SpecimensTopics:•Specimens...

Pagina 217 - Compliance

SpecimensSpecimen Editor OverviewAccessTools menu > Specimen EditorA specimen is the physical object to be tested. Examples of specimens may includ

Pagina 218 - Polynomial

Note:Before you can access the Specimen Editor, you must first define a test. The test does not have tobe complete, but a test must exist before you c

Pagina 219 - Controller Functions

DescriptionParameterDisplays the calculated area when you specify theparameters in the Detail for Selected SpecimenAreapanel. Specify the reduced cros

Pagina 220 - SignalFullScale

DescriptionParameterClick the list arrow to select a differentmeasurement unit.UnitDescribe the parameter.DescriptionAdd a new specimen definition. Th

Pagina 221 - Cyclic Functions

DescriptionParameterSpecify the inner diameter of the reducedcross-sectional area on the specimen.Inner Diameter -Hollow roundspecimensInner Diameter

Pagina 222 - Date and Time Functions

DescriptionParameterSpecify an identification of the plane and directionof a fracture in relation to the product configuration.Crack PlaneOrientationS

Pagina 223 - TestModificationDate

Table of ContentsTechnical SupportHow to Get Technical Support...

Pagina 225 - TestRunCreationTime

DescriptionParameterHalf-span of load points.Pin Center fromCrack PlaneUsed in calculations to present appropriately signeddata (SE(B) polarity = -1).

Pagina 226 - Directory Functions

M(T) Specimen OverviewThe M(T) specimen is the middle tension specimen. It is the symmetrical, center-crack specimen used forFatigue Crack Growth (FCG

Pagina 227 - ExternalFilesDirectory

LLC(T) Specimen Overview (p. 304)SE(B) Specimen Overview (p. 305)TaskFFC(T) Specimen OverviewThe FFC(T) specimen is the front-face compact tension spe

Pagina 228 - HysteresisArea

TaskReferenceM(T) Specimen Overview (p. 301)FFC(T) Specimen DCPD OverviewThe FFC(T) DCPD specimen is the front-face compact tension specimen. The spec

Pagina 229 - MeasInelasticStrainMin

FFC(T) Specimen DCPD (Johnson)For More InformationTaskReferenceM(T) Specimen Overview (p. 301)LLC(T) Specimen OverviewThe LLC(T) specimen is the load-

Pagina 230 - Index Functions

LLC(T) SpecimenLLC(T) Specimen DescriptionDescriptionItemCrack lengthaOriginal crack lengthaoSpecimen thicknessBNet specimen thicknessBnNotch heighthS

Pagina 231 - BreakIndexByDropFromPeak

Rectangular SE(B) SpecimenRectangular SE(B)Specimen DescriptionDescriptionItemCrack lengthaOriginal crack lengthaoSpecimen thicknessBNotch heighthSpec

Pagina 232 - BreakIndexByDropPerExt

Specimen Geometry ManagerSpecimen Geometry Manager OverviewThe Specimen Geometry Manager window lists the geometries that are available. Several commo

Pagina 233 - FractureIndex

ReferenceSpecimen Geometry Manager Properties (p. 308)Use of Domains (p. 116)Selecting a Domain (p. 116)Specimen Geometry Manager PropertiesSpecimen G

Pagina 234

DescriptionItemTransfers specimen geometry definitions betweenworkstations.ExportImports specimen geometry definitions frompreviously exported files.I

Pagina 235 - MaxSlopeStartIndex

Multipurpose Elite OverviewTopics:•Introduction...

Pagina 236 - MaxSlopeEndIndex

Update All Overview (p. 310)TaskUpdate All Geometry-Specific Functions (p. 311)Update All OverviewThe Update All button synchronizes the common functi

Pagina 237 - MinSlopeStartIndex

Selecting a Domain (p. 116)Update All Geometry-Specific FunctionsTo update all geometry-specific functions:1. Click the Functions tab.2. Click Update

Pagina 238 - MinSlopeEndIndex

Specimen Geometry Editor PropertiesSpecimen geometry properties can only be changed for user-defined specimen geometries. User-definedspecimen geometr

Pagina 239 - OffsetYieldIndex

DescriptionItemOpen the Rules for Variable “[Variable Name]”window to define rules to restrict the values that canbe assigned to the selected variable

Pagina 240 - PeakSlopeIndex

2. Select the specimen geometry for which you want to delete the variable rule, and click Copy.Predefined geometries are read-only. To edit the geomet

Pagina 241 - ValleyIndex

Test ActivitiesTopics:•Overview...

Pagina 242 - YpeEndIndexByIncreasingLoad

OverviewTest ProceduresA test procedure includes the system actions you want the application to perform during a test. Theprocedure is made up of acti

Pagina 243 - YpeEndIndexByTwoSlopes

• Interacting with the test-run display• Running reportsActivity propertiesMost activities require you to specify properties to fully define how the a

Pagina 244

When the durations of multiple signals differ, the signals with the shorter duration hold at the last end leveluntil all signals on the waveform defin

Pagina 245 - YpeStartIndex

Custom Waveform Activity PropertiesCustom Waveform + DAQ PropertiesDescriptionItemSpecify the number of times to perform the waveform defined. Click t

Pagina 246 - Math Functions

IntroductionThe Multipurpose Elite (MPE) application is a sophisticated, general purpose test design application thatallows you to quickly and easily

Pagina 247

DescriptionItemSelect an Interrupt behavior:• Interrupt Immediately—End the branch or loop immediately at the current level.• Interrupt at End of Cycl

Pagina 248 - ChannelValue

Test Sequence1. Add the Custom Waveform activity to your test.2. In the Custom Waveform properties, select the Use Variables to Specify Arrays of End

Pagina 249 - CurveArea

b. Use the Variables Selection window to add the EndLevelsArray and DurationsArray variables (thatyou created earlier) to the Selected Variables list

Pagina 250 - ElasticStrainValue

Important:This composite activity includes hard-coded settings that simplify the setup of data acquisition forcyclic testing.Custom Waveform + DAQ Act

Pagina 251 - EnergyValue

DescriptionItem• Interrupt Immediately—Complete immediately at the current level.• Interrupt at End of Cycle—Complete the current cycle before ending

Pagina 252 - FindNearestValueIndex

Data Acquisition WindowNote:This activity is hardcoded to always process data in blocks.Data Acquisition Window PropertiesDescriptionItemSelect and co

Pagina 253 - LeastSquaresFit

DescriptionItemSpecify how many cycles to store when the test starts or restarts.Starting CyclesNote:The cycles specified here are in addition to thos

Pagina 254 - MaxLong()

DescriptionItemOpens the Cycle Decimation Filter Selection window to further specify whichcycles to acquire. The raw data is saved for the acquired cy

Pagina 255

Ramp ActivityThe following example shows similar Ramp commands as a sine wave.Ramp Activity as a Sine WaveSignal compensationYou can apply a compensat

Pagina 256

• Interrupt at End of Cycle—Complete the current cycle before ending the branch or loop.Phase lagYou can specify the phase relationship of the wavefor

Pagina 257

DescriptionIconNameThe analysis definition is available in either the Fatigue Analyzer or FractureAnalyzer application as an overlay to the informatio

Pagina 258

Note:Specify these settings for each channel.Cycle Activity Properties330 | MTS TestSuiteTest Activities

Pagina 259 - XInterceptValue

Cycle Activity PropertiesDescriptionItemSpecifies how the timing property is expressed. You can selectone of the following:Timing Type• Frequency• Tim

Pagina 260 - YInterceptValue

DescriptionItem• kHz—kiloHertz; 1 kHz equals 1000 HzSpecify the number of end levels. Click the toggle button to specifya numeric value and unit of me

Pagina 261 - Operator Functions

DescriptionItemSuppress Cycle Counter—Select to prevent the channel counterfrom being incremented when this activity is executed. When notchecked, the

Pagina 262

DescriptionBehaviorInterrupt Immediately—Complete immediately atcurrent level.Interrupt at End of Cycle—Complete the currentcycle before ending the br

Pagina 263 - Peel-Tear Functions

DAQ activityUse the DAQ activity to define the data to collect and how to collect it. You must add at least one DAQactivity, and you can add multiple

Pagina 264 - AveragePeaks

Cycle + DAQ PropertiesDescriptionItemSpecifies how the timing property is expressed. You can select one of thefollowing:Timing Type• Frequency• Time•

Pagina 265 - AverageValue

DescriptionItem• Interrupt at End of Cycle—Complete the current cycle before ending thebranch or loop.Relative End Levels—Select to specify that the v

Pagina 266 - CombinedExtension

DescriptionItemSelect the type of feedback to use in the control loop for the selected channel.Specify this for each channel you select.Control ModeNo

Pagina 267 - MedianPeak

Data Acquisition WindowNote:This activity is hardcoded to always process data in blocks.Data Acquisition WindowDescriptionItemSelect and configure the

Pagina 268 - NextPeak

TestA Test is stored within a project folder, and contains the following components:• Test Definition—Contains the main components of the test, such a

Pagina 269 - NumberOfPeaks

DescriptionItemSpecify how many cycles to store when the test starts or restarts.Starting CyclesNote:The cycles specified here are in addition to thos

Pagina 270 - StDevValue

Values are collected for all cycles while the test runs. However, values are saved only for the cyclesselected in the Select Cycles window and the Sta

Pagina 271 - Sensor Functions

Dwell Activity PropertiesDwell Activity PropertiesDescriptionItemName that is shown on the Dwell activity icon in the workflow on theProcedure tab.Dis

Pagina 272 - SerialNumber

DescriptionItemNote:You add the Progress table as a Test-Run Display activity.Indicate the duration of the Dwell command activity in either time orfre

Pagina 273 - String Functions

External CommandExternal Command Activity OverviewExternal Command Activity IconThe External Command activity enables your test to accept program inpu

Pagina 274

External Command Activity PropertiesExternal Command Activity PropertiesExternal Command Activity PropertiesDescriptionItemName that is shown for the

Pagina 275 - StringLength

DescriptionItemactivity status disappears from the table, regardless of whether the testis done.• Never—(Default) Omits the activity from the Test Pro

Pagina 276 - StringToNumber

ProfileProfile Activity OverviewProfile Activity IconImportant:Working with profiles requires using the Station Manager application. Only expert users

Pagina 277 - TrimStringStart

Ramp ActivityRamp Activity CalloutsDescriptionCalloutCyclic activityARamp activityBCommand signalCAt the start of the following waveform example, a si

Pagina 278 - Functions Tab

DescriptionCalloutCommand signalCSignal compensationYou can apply a compensator to enhance performance. Compensators are control techniques that impro

Pagina 279 - Edit Function Window Overview

A Test Contains the Test Definition, Test Run(s), Analysis Definition(s), and Analysis Run(s)Test DefinitionThe test definition is stored within the t

Pagina 280

• Use Ignore Program State only to return the load to zero when the test shuts down.Ramp Activity PropertiesRamp Activity PropertiesDescriptionItemSpe

Pagina 281

DescriptionItem• Ramp• Sine• True Square• True Ramp• True SineSpecify the duration of time that the ramp should taketo achieve its end level. Click th

Pagina 282 - Edit Python Functions

DescriptionItemSpecify the end level for the control mode. Click thetoggle button to specify a numeric value or a variable.Specify the end level for e

Pagina 283

Caution:A high-speed transition segment can result in an unwanted spike (or bump) in your commandsignal.Unwanted command-signal spikes can damage the

Pagina 284 - Python Overview

Sweep Activity PropertiesSweep Activity PropertiesDescriptionItemName shown in the procedure. A default name is inthe text box or you can type a new n

Pagina 285 - MTS TestSuite Variable API

DescriptionItemis a constant linear rate (as with a ramp shape) or avarying rate (as with a sine shape). The choices are:• Square• Ramp• Sine• Square

Pagina 286 - Array of Numbers

DescriptionItemSpecifies the control mode.Control ModeDefines the end level value for the first segment.Absolute EndLevel 1/RelativeEnd Level 1Defines

Pagina 287 - Array of Text

Changing filesRPC III or RPC Pro drive files (drv or tim) are used to play out to the station.When you have selected a file, the application performs

Pagina 288 - Python Scripting Examples

Hz system rate, the function generator and RPC data acquisition may not stay synchronized aftera hold and resume. There can be an additional phase shi

Pagina 289

Time History Output PropertiesMTS TestSuite | 359Test Activities

Pagina 290

of the test. After a test run is complete, values that are stored in variables can be changed using theFatigue Analyzer and the Fracture Analyzer in o

Pagina 291 - Compare Tool

Note:If you are executing a Time History Output activity that includes data acquisition, and you holdand resume a test, there are slight differences b

Pagina 292

DescriptionItemcurrent properties, such as the addition or deletionof a channel of data or changing the units of the data,validation errors may occur,

Pagina 293

DescriptionItemSelects the control mode associated with the selectedstation channel. By default, for each file channel theControl Modeapplication sele

Pagina 294 - Specimens

DescriptionItemSpecifies the engineering units to be used whenwriting the data to the response file. Select a Unit Setor a variable.Unit SetSpecifies

Pagina 295 - Specimen Properties

TaskTime History Sequence OutputTime History Sequence Output Activity OverviewTime History Sequence Output IconThe Time History Sequence Output is an

Pagina 296

Road Surface FilesNesting road surface filesWith RSURF you can nest files up to four levels. The following diagram shows two levels of nesting. FilesA

Pagina 297 - Specimen Parameters

Time History Sequence Output (THSO) Files OverviewNote:Playout of RPC drive files at 128 Hz requires a system rate of 1024 Hz. For controllers equippe

Pagina 298 - Fracture Specimen Parameters

TaskTime History Sequence Output PropertiesTime History Sequence Output PropertiesDescriptionItemEnabling the Show Distance Traveled check boxcauses t

Pagina 299

DescriptionItemstate shows distance traveled, and the target stateshows target distance.Disabling this check box causes the current state andtarget st

Pagina 300 - Specimen Geometries

DescriptionItembetween files in the sequence, but transitionsdirectly between the last command point ofone drive file and the first command point ofth

Pagina 301 - M(T) Specimen Overview

Components of a Test RunMTS TestSuite | 37Multipurpose Elite Overview

Pagina 302 - FFC(T) Specimen Overview

DescriptionItemchannel’s unit descriptor matches one of the unitsavailable for that dimension, the application selectsthose units.Selects the units as

Pagina 303 - FFC(T) Specimen DCPD Overview

TaskData Acquisition (DAQ) ActivitiesDAQ ActivityDAQ Activity OverviewDAQ Activity IconThe DAQ activity is a standalone activity that collects data us

Pagina 304 - LLC(T) Specimen Overview

Basic DAQ Activity PropertiesA DAQ activity requires at least one trigger and one signal. You can also specify multiple triggers.Basic DAQ Properties

Pagina 305 - SE(B) Specimen Overview

ConceptDAQ Activity Overview (p. 371)TaskAcquiring Data While Holding (p. 375)Collecting a Last Data Point (p. 375)ConceptSelect Signals (p. 142)Save

Pagina 306

DescriptionItemThis type of buffering processes data when the testis stopped, when the activity reaches its preset count,or when the activity ends.Buf

Pagina 307 - Specimen Geometry Manager

DescriptionItemSpecify the name of the block that is shown invariable chart views that shows boundaries of data,such as the history view or hysteresis

Pagina 308

793 Controller Signals OverviewThe following signals are available to the acquisition processes for systems that run on the 793 platform.Note:All time

Pagina 309

DescriptionSignalInterlock, HSM On,HSM HighThe value reveals the state of the associated control when data is acquired.In the case of Run/Stop and Hol

Pagina 310 - Update All Overview

seconds). This maintains a high resolution with respect to typical data acquisition rates. However, becauseRollover Time and Running Rollover Time res

Pagina 311 - Specimen Geometry Editor

Sensor signalsSensor signals for this activity are only available from the following conditioners: Models 493.21B and493.25 conditioners and Models 49

Pagina 312

User InterfaceMultipurpose Elite Main WindowThe main window of the Multipurpose Elite application can be divided into the following sections:• The top

Pagina 313 - Delete Variable Rules

For More InformationTaskReferenceSample Rates for 493 Hardware (p. 380)Sample Rates for 494 Hardware (p. 381)High-Speed DAQ Properties (p. 383)Sample

Pagina 314

TaskSample Rates for 494 HardwareThe following tables show the relationship between the number of signals you can select and the maximumpotential samp

Pagina 315

System Rate 3072Maximum Number of SignalsMaximum Sample rate59307229614414122881115360724576530720System Rate 2048Maximum Number of SignalsMaximum Sam

Pagina 316 - Overview

Maximum Number of SignalsMaximum Sample rate892048593072444096355120296144228192171024014122881115360For More InformationConceptHigh-Speed DAQ Activit

Pagina 317 - Command Activities

High-Speed DAQ PropertiesDescriptionItemSpecifies the type of sample selection. Availableoptions include:Sample Selection• Sample Rate—Specifies the r

Pagina 318

DescriptionItemSensors signals for this activity are only availablefrom the following conditioners: Models 493.21B and493.25 conditioners and Models 4

Pagina 319

All included signalsWhen you select All Included Signals (default), the activity monitors all the signals in the Signal list fortheir maximum and mini

Pagina 320

Max/Min DAQ Activity PropertiesDescriptionItemSelects signals from which this process acquiresdata. Use the left and right arrows to move desiredsigna

Pagina 321

DescriptionItemcalculations by clicking the Configure button andusing the Map Variables window.Opens the Map Variables window where you canmap signal

Pagina 322 - Custom Waveform + DAQ

DescriptionItemcontinuously processed until the activity ends or isinterrupted. When the activity ends, any data in thebuffer is processed.Circular Bu

Pagina 323

DescriptionItemItemNote: When control is provided by a handset, theapplication controls will be locked and overlaid by thehandset exclusive control ic

Pagina 324

DescriptionItemFor more information about block data processing, see Block DataProcessing (p. 151).Specify the count variable that is going to be thei

Pagina 325

Time History Input Activity PropertiesTime History Input Activity PropertiesDescriptionItemSpecifies the rate at which the controller samplesresponse

Pagina 326

DescriptionItemautomatically based on the Trend File Root Nameplus an index provided by the application.Specifies the directory in which the response

Pagina 327 - Cycle Activity Overview

Trend Monitoring Activity PropertiesTrend Monitoring PropertiesTrend Monitoring Activity PropertiesDescriptionItemSpecify a rate and unit of measure o

Pagina 328

DescriptionItemClick the green plus sign to open the Select Statisticswindow and move the desired statistics on which toStatistics Listgather data fro

Pagina 329

Event Detection ActivitiesBreak DetectionBreak Detection Activity OverviewBreak Detection Activity IconThe Break Detection activity monitors signals f

Pagina 330 - Cycle Activity Properties

DescriptionItemSelects the type of event the activity looks for in theselected signal. Options are:Reference• Peak• ValleySpecifies the percentage of

Pagina 331

Cycle Change Detection Activity PropertiesCycle Change Detection Activity PropertiesCycle Change Detection PropertiesDescriptionItemSelect a variable

Pagina 332

Digital InputDigital Input Activity OverviewDigital Input Activity IconThe Digital Input activity monitors and responds to digital input states, such

Pagina 333

DescriptionItem• One Time—(Default) Performs one check of theinputs. The action is triggered only if the conditionsare detected by the one-time check.

Pagina 334 - Cycle + DAQ

Version Information Overview...52V

Pagina 335

DescriptionItemItemShows status information about events, such as logging intothe application, defining and setting up projects, and loadingApplicatio

Pagina 336

No controller action is taken. The test continues to run.No ActionA message is generated and shown to the operator. The test continuesto run.IndicateT

Pagina 337

Adding a Digital Input ActivityTo add a Digital Input activity:1. Add a Digital Input activity to the desired location in the test workflow.2. From th

Pagina 338

Limit Detection Activity PropertiesLimit Detection Activity PropertiesDescriptionItemSelect Any Limit to cause the Limit Detection totrigger based on

Pagina 339

DescriptionItemSelect Absolute to set a defined value for a variablelimit. If you set an absolute value at 10 kN, the limitis triggered at 10 kN.Compa

Pagina 340 - Cycle Values in Test Results

SensitivityA sensitivity value specifies how much the signal must change to detect a peak or valley. It can be usedto keep the activity from seeing si

Pagina 341 - Dwell Activity Overview

DescriptionCalloutValleyBTolerance BandsCDetector TriggersDEnable afterYou can use the Enable after command to specify how many feedback cycles occur

Pagina 342 - Dwell Activity Properties

• Trigger continuously• Tolerance: ±50 lbs• Sensitivity: 5 lbsPeak-Valley Change Detector Activity ExampleExample PropertiesDescriptionCalloutStrain C

Pagina 343

TaskPeak-Valley Change Detector Activity PropertiesPeak-Valley Change Detector Activity PropertiesDescriptionItemSelects the signal to monitor with th

Pagina 344 - External Command

DescriptionItemDefines a tolerance band for the peaks and valleys.If a peak or valley occurs outside the tolerance band,the activity triggers.Toleranc

Pagina 345

DescriptionItemNote:This feature is available only if you select aChannel Reference.Counts cycles from the beginning of the activity,including cycles

Pagina 346

You can select a block of rows two ways:• Click in the column at the first row of the block, hold the mouse button down, roll over the block of rows,a

Pagina 347 - Ramp Activity Overview

Template.LCF-ElevatedTemp, Template.Trapezoidal-ElevatedTemp, Template.TMF,Template.Transitional, Template.Transitional-ElevatedTemp.To purchase one o

Pagina 348

DescriptionItemYou can assign the stable cycle value to any variablethat has been defined to have a dimension of count.Stable CycleState Change Detect

Pagina 349

To purchase one of these licenses and begin using this test activity, contact your MTS sales engineer.State Change Detection Activity PropertiesState

Pagina 350 - Ramp Activity Properties

Wait for EventWait for Event Activity OverviewWait for Event Activity IconUse the Wait for Event activity to indicate when the test flow should wait f

Pagina 351

ControlParallelPath>10This condition indicates that when the value of this variable becomes greater than 10, activities inthe parallel path are sto

Pagina 352 - Sweep Activity Overview

Wait for Event Activity PropertiesDescriptionItemDefine a condition that when met indicates that the activity should stop and theprocedure should cont

Pagina 353

Auto Offset Activity PropertiesDescriptionItemSpecifies the name shown in the activity icon in the Procedure tab.Display NameEnables the activity. Cle

Pagina 354 - Sweep Activity Properties

Reset Cycle CountReset Cycle Count Activity OverviewImportant:The Reset Cycle Count activity is not associated with the Cycle Counter available in the

Pagina 355

Reset Cycle Count Activity PropertiesDescriptionPropertyThe selected channel on which to reset the cycle(segment) count.ChannelThe channels that appea

Pagina 356 - Time History Output

The Set Calculation Parameter activity changes the value of a controller calculation parameter. Thisactivity provides support for calculated signal an

Pagina 357 - Time History Controller Rates

• Is case-sensitive.• Contains both alphabetical and numeric characters.• Can contain special characters, including spaces, apostrophes, quotes, or ot

Pagina 358

Change Detection activity to determine if the change has occurred before continuing with subsequentactivities. For example, if you use the Set Control

Pagina 359 - MTS TestSuite

An interlock is generated and testing stops. Power is removed fromthe station.InterlockThe program (test) stops and an interlock is generated. The sta

Pagina 360

Effects of Controller ActionsActuatorCommand SignalPowerTest StateActionSelectedUnaffected by thetripped limitUnaffected by thetripped limitUnchangedR

Pagina 361

Set Digital OutputSet Digital Output Activity OverviewSet Digital Output Activity IconThe Set Digital Output activity specifies how the digital output

Pagina 362

Digital OutputIf you want an operator to interactively monitor digital output during a test run, you can configure a DigitalIO test-run display.Set Sp

Pagina 363

Monitor ContinuousContinuous monitor watches specified variables for span and setpoint values and sets them in the controllerwhenever the variable val

Pagina 364 - Time History Sequence Output

Segment Generator CalloutsDescriptionNo.Segment Queue1Segment Generator2Span3Setpoint4Command Signal5Engineering UnitseuFor More InformationConceptSet

Pagina 365

Set Span and Setpoint Activity PropertiesDescriptionPropertyPrevents the actuator from moving while adjustingthe span and setpoint values. Use this fe

Pagina 366

DescriptionPropertymessage is logged in both the Test Run Logand the Application Log.Multiplier adjustment on the command waveform.Span defaults to 10

Pagina 367

ConceptSet Span and Setpoint Activity Overview (p. 424)ReferenceSegment Generator Diagram (p. 425)Set Span and Setpoint Activity Properties (p. 426)Ex

Pagina 368

• Contains both alphabetical and numeric characters.• Can contain spaces, apostrophes, quotes, or other special characters.• Can start with a number o

Pagina 369

ReferenceSegment Generator Diagram (p. 425)Set Span and Setpoint Activity Properties (p. 426)Example: Setting Span and Setpoint (p. 430)Example: Maint

Pagina 370

ConceptSet Span and Setpoint Activity Overview (p. 424)TaskSetting Initial (One Time) Span and Setpoint Values (p. 428)Setting Continuous Span and Set

Pagina 371 - DAQ Activity

DescriptionNumber• Compensator: No Compensator• Channel List: Axial selected• Control Mode: Displacement• Absolute End Level: 0 mmAdd a Set Span and S

Pagina 372 - Basic DAQ Activity Properties

DescriptionNumber• DAQ List: Data Acquisition 1• Trigger 1: Timed• Buffer Size: 1 count• Save data to variables: Yes, automatically map variables (sig

Pagina 373

DescriptionNumber• Time: 5 seconds• Ramp Shape: Ramp• Compensator: No Compensator• Advanced Ramp:• Allow activity to execute when the test is stopped

Pagina 374

End TestEnd Test Activity OverviewEnd Test Activity IconThe End Test activity lets you force the test run to end before completing all stages of the a

Pagina 375 - Collecting a Last Data Point

If-Else Condition Activity PropertiesIf-Else Condition Activity PropertiesDescriptionItemSpecifies the conditional expression that evaluatesto True or

Pagina 376

Note:When designing procedures, do not use activities in parallel paths within the same parallel activitythat operate on the same control channel. Res

Pagina 377

Periodic Time EventPeriodic Time Event Activity OverviewPeriodic Time Event Activity IconImportant:To produce a trigger, the Periodic Time Event activ

Pagina 378 - High-Speed DAQ Activity

ConceptPeriodic Time Event Activity Overview (p. 438)TaskPeriodic Time Event PropertiesPeriodic Time Event Activity PropertiesDescriptionItemSelect to

Pagina 379

The menu also provides a Custom filter. You can specify logical operators such as “Contains,” “Doesnot end with,” and “Matches Regular Expression” in

Pagina 380 - Sample Rates for 493 Hardware

DescriptionItemSelect when the event should quit occurring.End ofRecurrence• No End Time—Select to have the event ongoingwith no elected conclusion ti

Pagina 381 - Sample Rates for 494 Hardware

In contrast to the While Loop activity, the Repeat Loop activity uses an explicit loop counter. For thosewho are familiar with programming languages,

Pagina 382

DescriptionPropertythe loop counter variable to zero before entering therepeat loop.Defining this property exposes the internal iterationcounter for t

Pagina 383 - High-Speed DAQ Properties

Example: Nested Repeat Loops (p. 444)Creating a Repeat Loop that uses a Loop Index VariableFollow these steps to configure a Repeat Loop activity that

Pagina 384

Simple Repeat Loop IconFor More InformationConceptRepeat Loop Activity OverviewTaskCreating a Simple Repeat Loop (p. 442)Creating a Repeat Loop that u

Pagina 385 - Max/Min DAQ

Nested Repeat Loops IconThe associated test-run display in the Test-Run Display tab has variable meters configured to displaycounts tracked by the Loo

Pagina 386

For More InformationConceptRepeat Loop Activity OverviewTaskCreating a Simple Repeat Loop (p. 442)Creating a Repeat Loop that uses a Loop Index Variab

Pagina 387

Note:The Condition must evaluate to True or False. Use logical operators such as “==”, rather thanassignment operators such as “=”. The Calculation Ed

Pagina 388

Operator Entry ActivitiesCustom Message WindowCustom Message Window Activity OverviewCustom Message Window Activity IconThe Custom Message Window acti

Pagina 389

Note:If you change the variable identifier name, you must manually change the name in the CustomMessage Editor; otherwise, a warning indicates the tes

Pagina 390 - Time History Input

1. Click on the tab or title bar of the panel you want to undock.2. Drag the view to where you want it.Arrows appear on the screen that indicate that

Pagina 391

DescriptionItemClick to see the message as it appears to theoperator during test execution.PreviewNote:Variables in the message are not resolved until

Pagina 392 - Trend Monitoring

DescriptionItemAdd a separator line between groups of buttons. Thebuttons align vertically with a separator between eachgroup.Add SeparatorMove the se

Pagina 393

Note:The editor does not support dynamic content or images stored on a web server. It also does notsupport scripting extensions, such as JavaScript. I

Pagina 394

The variable reference has the following keyword options. You can use any combination of these optionswith multiple options separated by a comma:• Des

Pagina 395 - Event Detection Activities

Input VariablesInput Variables Activity OverviewInput Variables IconUse the Input Variables activity to assign values to one or more variables. When t

Pagina 396 - Cycle Change Detection

ReferenceInput Variables Properties (p. 455)Input Variables PropertiesInput Variables Properties WindowInput Variables Activity PropertiesDescriptionp

Pagina 397

DescriptionpropertyDefine any additional rules for the variable. Click theellipsis to open the Rules for Variable window (youmust have selected a vari

Pagina 398 - Digital Input

When used as a separate branch in a parallel path, this activity adds an operator button on the Test-RunDisplay tab that when clicked ends the paralle

Pagina 399 - Controller Actions

DescriptionPropertyEnter the text that you want to display next to the button.Display TextImportant:To use this activity to terminate a Parallel Paths

Pagina 400

Edit Variable. The Edit Variable window opens. In the Availability panel, select the During-Testcheckbox.Assign Variables Activity PropertiesAssign Va

Pagina 401 - Limit Detection

User-Supplied Help OverviewRuntime helpTo assist the operator with tests you design, you can add a Help button to any part of the test-run displayto p

Pagina 402

Variables can also be used to retain data from one clock tick to the next. As a result, a variable must berecalculated at each clock tick.Calculate Va

Pagina 403 - Peak-Valley Change Detector

Important:A Data Acquisition activity must precede the Export Data activity in the test workflow.Use the Export Data activity to programmatically expo

Pagina 404

DescriptionItemYou can set the default directory path in theConfiguration window (Preferences > Configuration> Project > Data Export Director

Pagina 405

DescriptionItemSelect GroupItemsNote:Applicable to cyclic tests inMPE/MPX/FAA/FRA only.Enters cycles separated by space characters andenables grouping

Pagina 406

Log MessageLog Message Activity OverviewLog Message Activity IconThe Log Message activity writes an entry to the message log when a test performs the

Pagina 407

DescriptionItemInsert Variable button: Click to open the Select a Variable window. Themessage will include the value of this variable when the message

Pagina 408

• Tuning parameter values—(Applicable only to MTS Criterion and MTS Insight systems) You can savevarious sets of outer loop tuning parameters to an XM

Pagina 409 - Stable Cycle Detection

DescriptionPropertyThe File Name of the XML file that contains thevariables to read. If the file is not defined as avariable, the Update from File but

Pagina 410

• If a variable to read does not exist in the selected file, an error message is logged and the operatorcan continue with their workflow.Run External

Pagina 411 - State Change Detection

Run External Application PropertiesRun External Application PropertiesDescriptionItemSpecifies the application that the activity launches.Application

Pagina 412

LicensesTopics:•License Utility Overview...

Pagina 413 - Wait for Event

DescriptionItemSpecifies the default path to the selected argument. Define the defaultpath by typing the desired path in the entry box or by browsing

Pagina 414

The Run Report activity generates a test report based on the selected report template. The generatedreport is a Microsoft Excel file by default. You c

Pagina 415 - Control Settings Activities

To send the report attached to an e-mail, you must configure the e-mail server settings. Click Preferencesmenu > Configuration option > E-Mail t

Pagina 416

Report Template PropertiesDescriptionItemSelects a report template to use for the report. Ifdesired, you can explicitly override the defaultNametempla

Pagina 417 - Reset Cycle Count

DescriptionItemDisplays the default address from which the e-mailis sent or a variable. The default From address isconfigured in Preferences > Conf

Pagina 418 - Set Calculation Parameter

Make Default IconAny Run Report activities within a test that use the default template are automatically updated to pointto the new default template.5

Pagina 419 - Set Control Event

Send E-MailSend E-Mail Activity OverviewSend E-Mail Activity IconThe Send E-Mail activity is used to send an e-mail message at a designated point duri

Pagina 420

Send E-Mail Activity PropertiesSend E-Mail Activity PropertiesDescriptionItemE-Mail panel(Required) Sends an e-mail message to the specifiede-mail add

Pagina 421 - Effects of Controller Actions

DescriptionItemAttaches the messages to the e-mail message.Selecting the Attach Log check box enables theother log boxes in the panel.Attach LogCompre

Pagina 422

5. Repeat for each location in the test for which you want an e-mail notification.WaitWait Activity OverviewWait Activity IconUse the Wait activity to

Pagina 423 - Set Digital Output

License Utility OverviewAccessPrograms > MTS TestSuite > License AdministratorDuring installation, the Activation Wizard prompts you to activate

Pagina 424 - Set Span and Setpoint

Write Variables to FileWrite Variables to File Activity OverviewWrite Variables to File Activity IconThis activity directs the MTS TestSuite applicati

Pagina 425 - Segment Generator Diagram

DescriptionPropertyThe file name of the generated file. You can alsospecify a variable.File NameRequired.Appends or overwrites variables values depend

Pagina 427

Test-Run DisplaysTopics:•Test-Run Display Tab...

Pagina 428

Test-Run Display TabUse the Test-Run Display tab (see Test-Run Display Tab (p. 484)) to create charts and tables shownduring a test-run to communicate

Pagina 429

Toolbox PanelThe Designer tab provides a workspace to createtest-run displays.The Preview tab shows an example test-run displayand how it may appear d

Pagina 430

Presentation of non-cycle data variables requires that the variables are used in the test definition and thevariables are selected for presentation in

Pagina 431

• The scope configuration settings are not saved with a test. The configuration settings are only goodfor the current application session.Buttons avai

Pagina 432

DescriptionNameButtonWhen Expand Only is enabled, the range will automatically expand orcontract if the data exceeds the maximum and minimum ranges. T

Pagina 433

DescriptionItemOpen the Properties panel of the chart on which you clicked. If youchange the properties of a display component while the test runs,dat

Pagina 434 - Test Flow Control Activities

ReferenceActivate a License with an Internet ConnectionIf you have an activation key and the PC on which you are installing a license has an internet

Pagina 435 - If-Else Condition

For More InformationConceptAbout Scopes (p. 486)TaskCycles CategoryThe Cycles category includes counters and charts that display cyclic-related data.U

Pagina 436 - Parallel Paths

Cycle Count IconCycle Counter PropertiesCycle Counter Properties PanelDisplay NameThis is the name that is shown for the object in the application. It

Pagina 437

2. Navigate to the Cycle Counter in the Test Run Display tab:Click Test-Run Display > Toolbox > Cycles > Cycle Counter.3. Drag the test-run d

Pagina 438 - Periodic Time Event

Note:The Display Name is only used in the event of validation errors.Visibility PanelVisibility PanelFor Docking, select where on the monitor you want

Pagina 439

Variable List PropertiesClick the green plus sign in the Variable List panel to open the Variables Selection window.The variables that you select in t

Pagina 440 - Repeat Loop

Cycle Decimation (Select Cycles Button)Test-Run displays and DAQ activities use cycle selection in different ways:• For test-run displays, cycle selec

Pagina 441

Cycle Time Chart PropertiesCycle Time Properties PanelDisplay NameThis is the name that is shown for the object in the application. It is a required p

Pagina 442 - Creating a Simple Repeat Loop

Monitor for ChangeYou can monitor a variable for change by selecting an existing variable from the drop-down list or createa new one by selecting <

Pagina 443 - Example: Simple Repeat Loop

DescriptionItemSelect the thickness of the lines from 1 to 10 points.Line ThicknessSelect the line style as solid, dotted, or dashed.Line TypeSelect t

Pagina 444 - Example: Nested Repeat Loops

X-Axis and Y-Axis PropertiesX-Axis and Y-Axis PropertiesDescriptionItemSelect a display unit for the selected trace signal. The list only shows the se

Pagina 445

Working with ResourcesResources Overview...

Pagina 446 - While Loop

Activation Wizard Activation KeyA message indicates the license is being obtained from the server, and a progress bar is displayed.The Activation Wiza

Pagina 447

DescriptionItemClick the check box(es) and then specify the amplitude or mean values tomanually set the amplitude or mean display range for the X axis

Pagina 448 - Operator Entry Activities

RuntimeHistory charts are available as part of the Monitor and Results tabs.Group variable mapping occurs in the Procedure definition part of the test

Pagina 449

You can monitor a variable for change by selecting an existing variable from the drop-down list or createa new one by selecting <new variable> t

Pagina 450

Line and Symbol PropertiesLine and Symbol Display PropertiesDescriptionItemAdjust the opacity to better see through traces when they overlap. If you s

Pagina 451

Chart Titles and Legend WindowVariable List PropertiesClick the green plus sign in the Variable List panel to open the Variables Selection window.The

Pagina 452

X-Axis and Y-Axis PropertiesX-Axis and Y-Axis PropertiesDescriptionItemSelect a display unit for the selected trace signal. The list only shows the se

Pagina 453

DescriptionItemClick the check box(es) and then specify the amplitude or mean values tomanually set the amplitude or mean display range for the X axis

Pagina 454 - Input Variables

Group variable mapping occurs in the Procedure definition part of the test. If more than one type of groupis available, the Monitor for Change box of

Pagina 455 - Input Variables Properties

For Docking, select where on the monitor you want the test-run display to be positioned, Top, Left, Bottom,Right, or Fill, where the display fills the

Pagina 456 - Wait for Operator Action

Line and Symbol Display PropertiesDescriptionItemAdjust the opacity to better see through traces when they overlap. If you setthe opacity to a lower v

Pagina 457

Complete License Activation Window5. To copy the License Request Contents, which is a PC-identifying string, click Copy to.6. Paste the copied License

Pagina 458 - Program Actions Activities

Y Variable and X VariableY VariableSelect a single value variable for which you want data plotted on the Y axis of the chart.X VariableSelect a single

Pagina 459 - Calculate Variables

X-Axis and Y-Axis PropertiesX-Axis and Y-Axis PropertiesDescriptionItemSelect a display unit for the selected trace signal. The list only shows the se

Pagina 460 - Export Data

DescriptionItemClick the check box(es) and then specify the amplitude or mean values tomanually set the amplitude or mean display range for the X axis

Pagina 461

Trend Monitoring Limits Table PropertiesTrend Monitoring Limits TablesThe Trend Monitoring Limits Table allows you to set and edit Trend Monitoring Li

Pagina 462

Signals PanelSelect the signal(s) that you want to monitor. Click the green plus sign to open the Select Signals window(see the following figure).Sele

Pagina 463

Select Statistics WindowIn the Available column, click the statistic, and then click the arrow to move it to the Selected column.Click the double arro

Pagina 464 - Log Message

Trend Monitoring Statistics Chart PropertiesDisplay NameThis is the name that is shown for the object in the application. It is a required property so

Pagina 465 - Read Variables from File

Note:The Display Name is only used in the event of validation errors.Statistics PanelSelect the statistic(s) that you want to monitor. Click the green

Pagina 466

For Docking, select where on the monitor you want the test-run display to be positioned, Top, Left, Bottom,Right, or Fill, where the display fills the

Pagina 467 - Preselecting a File to Read

DescriptionItemSelect the type of symbol to mark the location of data points. If you do notwant to mark the data points with symbols, choose the blank

Pagina 468 - Run External Application

3. You are prompted to confirm removing the license. Click OK.4. Click Close.For More InformationConceptLicense Utility Overview (p. 48)Version Inform

Pagina 469

Vertical limit typeWhen you select the Vertical limit type, the X Variable specifies the value where the limit line crosses theX axis, as shown in the

Pagina 470 - Run Report

a chart with a line without symbols. A line with a single value will show up as a point, as in the followingfigure. This differs from Traces, where a

Pagina 471 - Run Report Activity Overview

Click the Edit (ellipsis) button on the Limit or Curve Fit Lines title bar to open the Line Drop Percentagewindow. Type the value in the box, and spec

Pagina 472

Vertical at Index limit typeWhen you select the Vertical at Index limit type, the Index Variable specifies the index in the data for thevalue where th

Pagina 473

X-Axis and Y-Axis PropertiesDescriptionItemSelect a display unit for the selected trace signal. The list only shows the set ofunits that are compatibl

Pagina 474

DescriptionItemSet the number of significant digits displayed in the labels along the X-axis andY-axis. Only non-zero digits are shown after the decim

Pagina 475 - Selecting a Report Format

Point Pick PropertiesPoint Pick WindowPoint Pick PropertiesDescriptionItemClick the check box to show a circle around an individual data point and the

Pagina 476 - Send E-Mail

Chart Titles and Legend WindowVariables CategoryThis section describes the available test-run displays for variables.Additional requirement for runtim

Pagina 477

Array-Variable Chart PropertiesArray-Variable Chart Properties PanelDisplay NameThis is the name that is shown for the object in the application. It i

Pagina 478

Show Condition lets you show or hide the test-run displays, depending on the condition of the variableexpression. For example, you could set up a cond

Pagina 479 - Wait Activity Properties

User and Role ManagementTopics:•Managing Users...

Pagina 480 - Write Variables to File

DescriptionItemSelect the size of the data point symbols. To automatically size the symbols,select the multiple size image, which is the first item in

Pagina 481

DescriptionItemSelect a single value variable or an array variable for which you want data plottedon the X axis of the chart.X VariableClick to add a

Pagina 482

General XY (Single Value or Array)The General XY limit type allows you to select a single value variable or an array variable. You can use itto plot c

Pagina 483

Percentage Least-Squares Fit limit typeWhen you select Percentage Least-Squares Fit, a line will be drawn through two points that are identifiedby the

Pagina 484 - Test-Run Display Tab

Vertical at Index limit typeWhen you select the Vertical at Index limit type, the Index Variable specifies the index in the data for thevalue where th

Pagina 485

X-Axis and Y-Axis PropertiesX-Axis and Y-Axis PropertiesDescriptionItemSelect a display unit for the selected trace signal. The list only shows the se

Pagina 486 - About Scopes

DescriptionItemClick the check box(es) and then specify the amplitude or mean values tomanually set the amplitude or mean display range for the X axis

Pagina 487

X-Axis and Y-Axis Advanced PropertiesX-Axis and Y-Axis Advanced WindowX-Axis and Y-Axis Advanced PropertiesDescriptionItemSet the base for displaying

Pagina 488

DescriptionItemShow the values of two points, the difference between their values, and theslope of a line drawn through the two points.Show Delta andS

Pagina 489

Variable Data TableAbout Variable Data TablesVariable Data Table PropertiesThe Variable Data Table shows the values of selected variable arrays in the

Pagina 490 - Cycles Category

Managing UsersUser Management OverviewIf your organization needs to manage multiple users of the MTS TestSuite application, you can manageusers with o

Pagina 491 - Configure a Cycle Counter

Variable Data Table PropertiesVariable Data Table Properties PanelDisplay NameThis is the name that is shown for the object in the application. It is

Pagina 492 - Cycle Statistics Table

Variable List PropertiesClick the green plus sign in the Variable List panel to open the Variables Selection window.The variables that you select in t

Pagina 493 - Monitor for Change

Variables Selection WindowVariables Selection PropertiesDescriptionItemThis panel shows the Category and Display Name of all variables thatare availab

Pagina 494 - Cycles to Display Property

Variable MeterAbout Variable MetersIn addition to the Display menu > Meters tab, you can create a test-run display to monitor the value of avariabl

Pagina 495 - Cycle Time Chart

Variable Meter PropertiesVariable Meters Properties PanelDisplay NameThis is the name that is shown for the object in the application. It is a require

Pagina 496 - Cycle Time Chart Properties

Note:The Display Name is only used in the event of validation errors.Visibility PanelVisibility PanelFor Docking, select where on the monitor you want

Pagina 497 - Line and Symbol Properties

DescriptionItemFrom the drop-down list, select the units to be displayed.UnitWith Fixed, the number is shown in standard notation. For example, twenty

Pagina 498 - Chart Titles and Legend

DescriptionItemSelect the size of the label shown in the meter.Label Font SizeSelect the size of the value shown in the meter.Value Font SizeSelect a

Pagina 499 - X-Axis and Y-Axis Properties

Variable Value Scope PropertiesVariable Value Properties PanelDisplay NameThis is the name that is shown for the object in the application. It is a re

Pagina 500 - History Chart

Note:The Display Name is only used in the event of validation errors.Visibility PanelVisibility PanelFor Docking, select where on the monitor you want

Pagina 501 - Display Name

Manage User Accounts WindowThe Primary MTS TestSuite Administrator is displayed in blue.Manage User Accounts Window DescriptionDescriptionSectionUser

Pagina 502

Line and Symbol Display PropertiesDescriptionItemAdjust the opacity to better see through traces when they overlap. If you setthe opacity to a lower v

Pagina 503

DescriptionItemClick to add a legend label to the chart, and type the name in the box.Legend LabelLimit TypesLimit Types are not available for all cha

Pagina 504

General XY (Single Value or Array)The General XY limit type allows you to select a single value variable or an array variable. You can use itto plot c

Pagina 505

Percentage Least-Squares Fit limit typeWhen you select Percentage Least-Squares Fit, a line will be drawn through two points that are identifiedby the

Pagina 506 - Hysteresis Chart

Vertical at Index limit typeWhen you select the Vertical at Index limit type, the Index Variable specifies the index in the data for thevalue where th

Pagina 507 - Hysteresis Chart Properties

X-Axis and Y-Axis PropertiesX-Axis and Y-Axis PropertiesDescriptionItemSelect a display unit for the selected trace signal. The list only shows the se

Pagina 508

DescriptionItemClick the check box(es) and then specify the amplitude or mean values tomanually set the amplitude or mean display range for the X axis

Pagina 509

X-Axis and Y-Axis Advanced PropertiesX-Axis and Y-Axis Advanced WindowX-Axis and Y-Axis Advanced PropertiesDescriptionItemSet the base for displaying

Pagina 510 - Y Variable and X Variable

DescriptionItemShow the values of two points, the difference between their values, and theslope of a line drawn through the two points.Show Delta andS

Pagina 511

Signal GageAbout Signal GagesThe Signal Gage shows the current level of a signal in a meter and in a linear or radial gage. The signalshown during run

Pagina 512 - Trend Monitoring Limits Table

DescriptionSectionRemoves the user selected in the Manage User Accountswindow.Remove User buttonOpens the Change User Properties window. You can chang

Pagina 513

Display NameThis is the name that is shown for the object in the application. It is a required property so the box cannotbe empty. The default is the

Pagina 514

Variable Value InformationDescriptionItemSelect the type of meter to display: Timed, Minimum, Maximum, Peak, Valley, Peak/Valley,Running Maximum/Minim

Pagina 515

Variable InformationDescriptionItemSpecify the number of rows to be in the meter display.RowsCheck the box to have labels not be shown on the meter di

Pagina 516

DescriptionItemSpecifies the maximum value or variable and units for the signal.MaximumSets the incremental number of tickmarks that are displayed for

Pagina 517 - Statistics Panel

Signal Meter PropertiesSignal Meter Properties PanelDisplay NameThis is the name that is shown for the object in the application. It is a required pro

Pagina 518 - Traces Properties

Note:The Display Name is only used in the event of validation errors.Visibility PanelVisibility PanelFor Docking, select where on the monitor you want

Pagina 519

DescriptionItemFrom the drop-down list, select the units to be displayed.UnitWith Fixed, the number is shown in standard notation. For example, twenty

Pagina 520

DescriptionItemSelect the size of the label shown in the meter.Label Font SizeSelect the size of the value shown in the meter.Value Font SizeSelect a

Pagina 521

Signal Scope PropertiesSignal Scope Properties PanelVisibility PanelVisibility PanelFor Docking, select where on the monitor you want the test-run dis

Pagina 522

If you define more than one trace on an axis, all the traces must have the same dimension. For example,you cannot add a force signal trace and a displ

Pagina 523

Create New MTS TestSuite User Window4. Enter the User Name for the user.5. Enter a Password for the user and enter the password again in the Confirm P

Pagina 524

Vertical limit typeWhen you select the Vertical limit type, the X Variable specifies the value where the limit line crosses theX axis, as shown in the

Pagina 525

a chart with a line without symbols. A line with a single value will show up as a point, as in the followingfigure. This differs from Traces, where a

Pagina 526 - Point Pick Properties

Click the Edit (ellipsis) button on the Limit or Curve Fit Lines title bar to open the Line Drop Percentagewindow. Type the value in the box, and spec

Pagina 527 - Variables Category

Vertical at Index limit typeWhen you select the Vertical at Index limit type, the Index Variable specifies the index in the data for thevalue where th

Pagina 528

DescriptionItemSelect the thickness of the lines from 1 to 10 points.Line ThicknessSelect the line style as solid, dotted, or dashed.Line TypeSelect t

Pagina 529

DescriptionItemSet the display range of the Y axis to the maximum or minimum values.Maximum orMinimumClick the corresponding button to use this featur

Pagina 530 - Plot Previous Test Runs

DescriptionItemSelect the check box to show grid lines on the chart. Deselect the check box tosuppress the grid lines.Draw Grid LinesX-Axis and Y-Axis

Pagina 531

Point Pick PropertiesDescriptionItemClick the check box to show a circle around an individual data point and thevalue of the point when selected by th

Pagina 532

Digital IOAbout Digital IO DisplaysThe Digital IO test-run display monitors the current state of one digital input or digital output. If necessary,you

Pagina 533

Digital IO Test-Run Display PropertiesDescriptionItemThe signal selected to monitor. Click the ellipsis to open the Select a Signalwindow. The Signal

Pagina 534 - 534

Add MTS TestSuite Users Window4. Select the role you want to assign to the new users.5. To add a user:• To find Windows users you want to add, enter t

Pagina 535

Show Condition lets you show or hide the test-run displays, depending on the condition of the variableexpression. For example, you could set up a cond

Pagina 536

Set Digital Output at RuntimeFollow these steps to create a Digital I/O test-run display that allows an operator to toggle a digital outputduring a te

Pagina 537

TaskCreate a Digital IO Test-Run Display (p. 580)Set Digital Output at Runtime (p. 581)Input VariablesAbout Input VariablesIn addition to presenting i

Pagina 538

DescriptionItemRequired. A variable must be selected. A validation error is logged inthe Error list until a variable is selected. Click the ellipsis t

Pagina 539 - Variable Data Table

Select a Variable WindowCreate an Input Variable Test-Run DisplayTo create an Input Variable test-run display:1. Click the Test-Run Display tab > D

Pagina 540

a. Click the Variables tab to access the variable editor.b. Enter the variable identifier as OperatorEdit.c. From the Type list, select Boolean.d. Lea

Pagina 541 - Variables Selection Window

Note:Only variables that have the Editable property of During Test are available for use with this activity.Set Variable Button PropertiesSet Variable

Pagina 542

Note:The Display Name is only used in the event of validation errors.Visibility PanelVisibility PanelFor Docking, select where on the monitor you want

Pagina 543 - Variable Meter

Note:The customized help button for test-run displays is not part of the MTS TestSuite Help menu options.The runtime Help Button provides access to in

Pagina 544 - Variable Meter Properties

DescriptionItemhttp:\\www.myweb.com\Documents\MyHelp.htmlEnter the directory path or the URL for the file that contains the imageto be used for the he

Pagina 545 - Value Properties

ConceptUser Management Overview (p. 54)ReferenceManage User Accounts Window (p. 54)Remove a UserTo remove a user:1. Click Preferences > User Manage

Pagina 546

Note:The Display Name is only used in the event of validation errors.Visibility PanelVisibility PanelFor Docking, select where on the monitor you want

Pagina 547 - Variable Value Scope

Note:Image files for test-run displays are not included when you import or export a test.For More InformationTaskAdd an Image to a Test-Run Display (p

Pagina 548

DescriptionItemSelecting this check box enables the Show Condition box, whichshows a picture in the test-run display depending on whether definedcrite

Pagina 549

hidden for a rectangular specimen. Likewise, you can use two more Set Variable test-run displays forwidth and length to be visible if the specimen typ

Pagina 550

ConceptAbout Images (p. 590)TaskAdd an Image to a Test-Run Display (p. 593)LabelAbout LabelsLabel contains a single line of text that you can use to:•

Pagina 551

DescriptionItemSize of the text for the label.Font SizeRange: 4-100 pointsDefault: 8 ptFor More InformationConceptAbout Labels (p. 594)TaskAdd a Label

Pagina 552

5. Repeat for each label you want to add.For More InformationConceptAbout Labels (p. 594)ReferenceLabel Properties (p. 594)Test ProcedureTest Procedur

Pagina 553

Test Procedure Pan and Zoom ControlsProcedure runWhen the test is loaded, you use the control panel to perform primary hardware and test control opera

Pagina 554 - 554

• Data acquisition• Program control and error handling• Interacting with the monitor display• Running reportActivity propertiesMost activities require

Pagina 555

for a Set Variable test-run display to make visible the diameter only when the specimen type is round, buthidden for a rectangular specimen. Likewise,

Pagina 556

Import Test Resources...115Domains.

Pagina 557

Access1. Click Preferences > User Management > Manage User Accounts.2. Either the Local or Windows User Management option must be selected.3. Cl

Pagina 558 - Signal Category

Visibility Property FieldThe following selections are available:• Never—(Default) Omits the activity from the Test Progress Table• Fixed —Shows the pr

Pagina 559 - Signal Gage

Display NameThis is the name that is shown for the object in the application. It is a required property so the box cannotbe empty. The default is the

Pagina 560

Test Summary TableYou select the variables from the types that are currently defined for the test under Variables. Althoughyou can list any of the ava

Pagina 561

For Docking, select where on the monitor you want the test-run display to be positioned, Top, Left, Bottom,Right, or Fill, where the display fills the

Pagina 562

Layout CategoryUse the tools in the Layout category to organize multiple test-run displays. You can create multiple tabswith transitions and place pan

Pagina 563 - Signal Meter

Display NameThis is the name that is shown for the object in the application. It is a required property so the box cannotbe empty. The default is the

Pagina 564 - Signal Meter Properties

The variables that you select in the Variables Selection window (double-click or use arrows to movevariables from the Available Variables column to th

Pagina 565

Tabs Properties PanelThe activity consists of two parts: the control window and the individual tabs within the control window.The tab control window i

Pagina 566

Activity transitionsYou can find pertinent test information for the current test activity by using tab transitions. Start by usingtabs to organize tes

Pagina 567 - Signal Scope

Running TestsTopics:•Control Panel...

Pagina 568 - Signal Scope Properties

Add Role Window4. Enter a Name and Description for the new role.5. Select the Privileges to assign to the role.6. Click OK.For More InformationConcept

Pagina 569

Control PanelControl Panel OverviewUse the Control panel to perform basic operations of the controller during a test run.Station controlsController Pa

Pagina 570

DescriptionControlOverrideCaution:Station limits are disabled during theoverride time.Disabling station limits also disablessafety limits.Always clear

Pagina 571

Application controlsApplication ControlsDescriptionControlPark. Move the test station actuator or actuators tothe prescribed park position.ParkCaution

Pagina 572

DescriptionControlUnload. Unload the test station actuator to theprescribed load value.UnloadCaution:The Unload command attempts to moveto the specifi

Pagina 573

DescriptionControlHold state, the button illuminates, and its colorsreverse.Stop. Stop the test in place. The current cycle orcommand activity is not

Pagina 574

DescriptionItemNote:Unload shows only the first available controlmode for the channel.This column is a list of the available channels (teststation res

Pagina 575

DescriptionItemInitialized—The test procedure is loaded. The project must be savedfor the test to continue.Test Run StatusRunning—The test is in-progr

Pagina 576

Systems without hydraulic powerOn test systems that do not control hydraulic power, the control panel displays “No power configured” andhas an Interlo

Pagina 577 - Interactive Category

Power WindowFor More InformationTaskTurn On Hydraulic Power (p. 618)Turn Off Hydraulic Power (p. 619)ReferenceTurn On Hydraulic PowerHydraulic power i

Pagina 578 - Digital IO

For More InformationConceptHydraulic Control Panel Overview (p. 616)Power Panel Overview (p. 617)Turn Off Hydraulic PowerTo turn off hydraulic power:1

Pagina 579

Note:The privileges that appear vary depending on the selected role. Only privileges for which you arelicensed are shown.Default User RolesPrivilegesD

Pagina 580

ConceptResults Tab (p. 625)Set Up a Test StationBefore you can connect to a test station, you must complete the pretest tasks in Pretest Tasks (p. 619

Pagina 581 - Example Digital IO Workflow

Set Up a New Test RunBefore you can create a new test, you must complete the following activities:• Pretest tasks• Station setupNote:This section does

Pagina 582

Run a TestConsiderations for automatic background savesWhen you start a test run, the application automatically saves the current state of the test. I

Pagina 583 - Select A Variable Window

The test designer can require the test operator to enter or select test parameters at any point duringthe test run. In this case, the test waits until

Pagina 584

Once the procedure is stopped, you can navigate to other tests or test runs, load other projects, or shutdown the application.Note:The stopped test pr

Pagina 585 - Set Variable Button

b) Click Off on the Power control panel.This activity places the HSM for the test station and the HPU (hydraulic power unit) in theirzero-pressure sta

Pagina 586

TaskPretest Tasks (p. 619)Set Up a Test Station (p. 620)Set Up a New Test Run (p. 621)Stop and Restart a Test Procedure (p. 623)Run a Test (p. 622)Per

Pagina 587 - General Category

2. Select one or more templates to use for your reports and click Generate Report.3. Microsoft Excel opens with the newly generated report. If multipl

Pagina 589

Appendix: Trend MonitoringTopics:•About this Section...

Pagina 590 - About Images

PrivilegesDefault Role Name• Change Polarity• Create Diagnostic File• Delete Project• Delete Test• Delete Test Run• Edit Procedure• Express Editor• La

Pagina 591 - Image Properties

About this SectionThis section contains introductory and procedural information about the Trend Monitoring option for MTSTestSuite software. It provid

Pagina 592

useful when designing Trend Monitoring tests. Path: Procedure tab > Toolbox > Test FlowControl category.Designing tests for Trend MonitoringThe

Pagina 593

Open the 2 Chan.cfg station configuration and start the MPEapplicationNote:The instructions in this section are intended to be performed in simulation

Pagina 594 - Label Properties

Basic and Advanced Workflows in the Example Trend Monitoring TestWorkflow DescriptionsDescriptionItemBasic Workflow, in which the Trip Action path of

Pagina 595

Examine the Basic WorkflowExample Trend Monitoring Test: Basic WorkflowBasic Workflow DescriptionDescriptionItemRamp activity.1Parallel Paths activity

Pagina 596 - Test Procedure

Examine the Logic in the Basic WorkflowAfter the Ramp activity (1) executes, the Parallel Path activity (2) performs the Command and TrendMonitoring p

Pagina 597

Example Test Monitor DisplayExample Test Monitor Display DescriptionDescriptionItemTrend Monitoring Limits Table1Cycle Statistics Table.2Signal Scope3

Pagina 598 - Test Procedure Properties

changes into a splitter cursor (resembling a cross-hairs). It may take several clicks to get the mouseto change to the splitter curser.Trend Monitorin

Pagina 599 - Test Progress Table

Run the Basic WorkflowThe Basic Workflow plots statistical values that move (or “trend”) toward and exceed the upper trend limitline as the sweep comm

Pagina 600

Trip Action Path in Advanced Workflow DescriptionDescriptionItemWhile Loop activity (expanded) in the Trip Action path.1Wait for Event activity.2Set C

Pagina 601 - Test Summary Table

TaskCreate a Custom User Role (p. 60)Edit a Custom User Role (p. 64)View Users Assigned to a Role (p. 64)Remove a Custom User Role (p. 65)Edit a Custo

Pagina 602 - Test Summary Table Properties

3. Click the Run button (green arrow) on the Test control panel.4. Observe the test on the Monitor Display:• The Trend Monitoring Limits Table shows t

Pagina 603 - Set Up a Test Summary Table

The Example Trend Monitoring test uses the Example Trend Report.xltx as the default report template(MPE Explorer panel > Report Templates > Repo

Pagina 604 - Layout Category

• Full-Scale Percentage• Statistical Limits from Table• Range Percentage from TableDefinitions for Limit CalculationsRange = Max - MinMidpoint = (Max

Pagina 605

Comparison of Trend Calculations to Other MTSApplicationsMPE and MultiPurpose TestWare (MPT)Terminology ComparisonMPE and MPT Terminology ComparisonMP

Pagina 607

Index.drv le extension 356, 364.NET Libraries 285.seq le extension 364.tim le extension 356<Bold>Scale <Default Para Font>propertyTime

Pagina 608

argumentsyntax 208, 215array functions 216array variables 168–169ArrayValueAtIndex function 217Assign Variables activity 458audit trail 75Audit Trail

Pagina 609

Completion propertyLimit Detection activity 402Compliance function 217compliance testing values 465conguration le 632Continuous Sampling propertyHig

Pagina 610 - Control Panel

data (continued)export raw 461lter 43data acquisitionDAQ activity 371point-by-point processing 150data lelegacy 128data pointcollecting last post-br

Pagina 611

Ffailure cyclechart 210Fatigue and Fracture functions 228fatigue crack growth (FCG) 305lemanagement 107moving test les 109File Channel propertyTime

Pagina 612

User In Role Window4. Click Close.For More InformationConceptManaging Roles (p. 59)ReferenceManage Roles Window (p. 59)Default Roles (p. 61)Privileges

Pagina 613

functions (continued)FindNearestValueIndex 252FindSubString 273First Cycle Modulus 210Floor 252FractureIndex 233GetTransitionTime 220HysteresisArea 22

Pagina 614 - Control Panel Settings

Hhandset exclusive control 39, 79, 614helpruntime 46High-Speed Data Acquisition activity 383History Chart 500holdacquiring data during 375Hold At Leve

Pagina 615 - Test Run Status Panel

Linear-Elastic Plane-Strain Fracture Toughness (KIC) 305Loading Modulus function 209log messagehow to use 465Log Message activity 464Log Message Descr

Pagina 616 - Hydraulic Controls

Periodic Time Event activityabout 438example 438properties 439recurrence 439Phase Lag propertySweep activity 356Plot Previous Test Runs panel 530point

Pagina 617 - Power Panel Overview

properties (continued)end level 1 and 2Cycle activity 333end of recurrencePeriodic Time Event activity 440leTime History Sequence Output activity 368

Pagina 618 - Turn On Hydraulic Power

properties (continued)runtime help button 588sample countHigh-Speed Data Acquisition activity 384sampling rateTime History Input activity 391sampling

Pagina 619 - Run a Test

Ramp activity (continued)signal compensation 349Ramp Shape propertyRamp activity 350Ramp To activity 400, 421rawexport data 461Read Variables from Fil

Pagina 620 - Set Up a Test Station

Sensor functionsCalibrationDate 271CalibrationDueDate 272ModelNumber 272Serial Number 273sensor signals 377seq le extension 364SerialNumber function

Pagina 621 - Set Up a New Test Run

Ttabsresults 103TearIndex function 271technical support 23TEDs device function 272TEDS device function 272templateabout 105conversion 125convert 126cr

Pagina 622

unit set (continued)SI (mm-N) 81US (in-kip) 81US (in-lbf) 81unit setsmanager properties 83United States Customary System of Units (US) 83UnLoading Mod

Pagina 623

PrivilegesNote:The privileges that appear vary depending on the selected role. Only privileges for which you arelicensed are shown.PrivilegesDescripti

Pagina 624 - Perform Post-Test Tasks

Wave Shape propertyCycle activity 331Sweep activity 354waveformstop behavior 333While Loop activity 446windowadd custom unit set 83copy unit set 83edi

Pagina 626 - Generating a Report in MP

MTS Systems Corporation14000 Technology DriveEden Prairie, Minnesota 55344-2290 USAToll Free Phone: 800-328-2255(within U.S. or Canada)Phone:952-937-4

Pagina 627 - Exporting Raw Data

DescriptionPrivilege NameLaunches the Fracture Analyzer application.Launch FractureAnalyzerAllows you to start the Multipurpose Eliteapplication.Launc

Pagina 629

Preferences and Default SettingsTopics:•Configuration Window...

Pagina 630 - Trend Monitoring Overview

Compensator Overview...133Compensator

Pagina 631 - Example Trend Monitoring Test

Configuration WindowAccessPreferences > Configuration > Project tabUse the tabs in the Configuration window to select preferences and default se

Pagina 632

DescriptionTabOpens the current test when the applicationstarts. Allows you to define the Default LogType (Basic or Audit Trail).Selects a language fo

Pagina 633

Project ManagementWorking with ProjectsAccessPreferences > Configuration > Projects tabAdd a projectTo add a project, click the “+” button in th

Pagina 634 - Examine the Basic Workflow

ConceptConfiguration Window (p. 70)TaskProject TabAccessPreferences > Configuration > Projects tabUse the Project tab to manage projects. With t

Pagina 635 - Examine the Monitor Display

DescriptionSettingNote:If tests are stored in a project directory(default), they are deleted if the projectis deleted.Note:This field is read-only if

Pagina 636

TaskAudit TrailAccessExplorer panel > Test Definition node > General Settings tab > Log TypeWhen activated, the Audit Trail feature allows yo

Pagina 637

ReferenceAudit Trail (p. 75)Check the Test Audit Trail1. Make sure that the Log Type for the test is set to Audit Trail.2. Click File > Check Test

Pagina 638 - Examine the Advanced Workflow

b) Enter your Password.7. Enter an e-mail address in the Send test e-mail to address field and click Send.• If successful, an e-mail sends the SMTP se

Pagina 639 - Run the Advanced Workflow

DescriptionSettingwindow automatically populates the From addressin the Properties panels of the Send E-Mail and SendReport to E-Mail of the Run Repor

Pagina 640

Control Panel SettingsAccessPreferences menu > Configuration > Control Panel tabUse the Control Panel tab to set up the operation of the Park an

Pagina 641

Array Variables Overview...168Array Variable Uses...

Pagina 642 - Calculate Trend Limits

DescriptionItemEnable or disable the park or unload function for thecorresponding channel.EnabledSet the target end level for the enabled channelswhen

Pagina 643 - Applications

ReferencePredefined Unit SetsMTS TestSuite includes the following predefined unit sets:Predefined Unit SetsDescriptionUnit SetCentimeters-Grams-Second

Pagina 644

ConceptUnit Set Overview (p. 80)Unit Set Manager Overview (p. 82)Add a Custom Unit Set (p. 84)TaskUnit Set Manager OverviewAccessPreferences menu >

Pagina 645

Unit Set Manager PropertiesUnit Set ManagerDescriptionItemShows the current default unit set for the applications.Click the list arrow to assign anoth

Pagina 646

DescriptionItemExport a custom unit set to another project oranalysis. Click the required custom unit set (.tsunitset)to export.ExportNote:If your pro

Pagina 647

Remote Server SettingsAccessPreferences menu > Configuration > Remote tabUse the Remote tab to enable and use remote extensions, if available. T

Pagina 649

Working with ResourcesTopics:•Resources Overview...

Pagina 650

Resources OverviewQuick access:Explorer panel > Test name > Test Definition > ResourcesThe Resources tab serves as a map between controller c

Pagina 651

TaskImport Test Resources (p. 96)Access System Resources (p. 93)ReferenceAdd Test Resources (p. 93)Resources Tab Buttons (p. 92)Resources Tab (p. 89)R

Pagina 652

Data Acquisition Variable Mapping...198Map Variables Win

Pagina 653

DescriptionItem• Normal• InvertedNote:The Polarity setting is always available with MTSTestSuite TW software running on an InsightController. With a F

Pagina 654

DescriptionItemThe list is empty because no controller is connected from whichto query the valid resource names. The edit box shows theController Reso

Pagina 655

Resources Tab ButtonsResources Tab ButtonsDescriptionItemAdd a resource to the table. Right-click the entries in theName column for a menu that contai

Pagina 656

For More InformationConceptResources Overview (p. 88)TaskImport Test Resources (p. 96)Access System Resources (p. 93)Access System ResourcesNote: This

Pagina 657

Import resourcesBy default, the test resources shown on the Resource page for MTS-supplied templates are limited to onlythose used in the test. The co

Pagina 658

4. In the Controller Resource Type column, select Calculation.5. In the Controller Resource column, double-click the empty cell that contains a valida

Pagina 659

Import Test ResourcesThe procedure applies only to the Import Resources button on the Resources tab in the Explorer panel.You can only import test res

Pagina 660

Working with Multipurpose EliteTopics:•Tests...

Pagina 661

TestsTests OverviewNote:You must have Engineer or Administrator privileges on an MPE system to create or modify a test.A Test is a file that contains

Pagina 662

Flowchart View of WorkflowOutline View of WorkflowThe Toolbox Panel for the test procedure shows the activities that are available. To construct a tes

Comentarios a estos manuales