SWIFT 50 GLP Sensors Installation
60
Road Simulator
Installing the Transducer
Equipment required This procedure requires one person. To install the transducer, you will need the
following equipment:
Spindle adapter spacers (see next figure)
Adapter to 329 simulator
Anti-rotate assembly (including customer-supplied mounting arm)
Small set of metric hex-head wrenches
Tube bender for the restraint tube
Tube cutter
Metric socket head drive set (up to 14 mm) with extension
Molykote g-n paste, 2.8 oz. tube (MTS part number 011-010-217)
Nikal based anti-galling compound (MTS part number 011-354-902)
Transducer mounting bolts (per transducer)
For dual rims
16 size M16 X 1.5 mm
8 size M10 X 1.5 mm
4 size M5 X 0.8 mm
lug nuts and shim washers
For front rims
16 size M16 X 1.5 mm
8 size M10 X 1.5 mm
4 size M5 X 0.8 mm
lug nuts and shim washers
For dual rims
Slip ring extension assembly
Four size M12 X 1.75 mm X 30 mm long bolts
Slip ring assembly fasteners
Four size M8 X 1.25 mm X 20 mm long bolts
Torque wrenches, capable of the following ranges:
24–74 N•m (18–55 lbf•ft),
203–815 N•m (150-600 lbf•ft);
108–325 N•m (80–240 lbf •ft)
93 N•m (69 lbf•ft)
Cables (transducer and BNC, plus customer-supplied from transducer
interface to data recorder)
Tie wraps
Data recorder
Power supply–12 V DC or optionally 24 V DC
1
power supply
1 If 24 Vdc compatible electronics was ordered at time of purchase.