be certain.
m
Multi-Pump Control Manager (MPCM)
Remote Human-Machine Interface (RHMI)
Product Information
100-244-185 A
Vista de pagina 0
1 2 3 4 5 6 ... 33 34

Indice de contenidos

Pagina 1 - Product Information

be certain.mMulti-Pump Control Manager (MPCM)Remote Human-Machine Interface (RHMI)Product Information100-244-185 A

Pagina 2 - Publication information

Remote Human Machine Interface8General Safety PracticesSafetyProvide adequatelightingEnsure adequate lighting to minimize the chance of operation erro

Pagina 3 - Contents

General Safety PracticesRemote Human Machine Interface Safety9Do not use RFtransmittersKeep radio frequency (RF) transmitters away from the workstatio

Pagina 4

Remote Human Machine Interface10General Safety PracticesSafety

Pagina 5 - Introduction

Tabletop and Pedestal MountRemote Human Machine Interface Installation11InstallationThe Remote Human Machine Interface (RHMI) allows you to operate a

Pagina 6

Remote Human Machine Interface12CablingInstallationCablingCabling consists of connecting the cables between the RHMI and the Hydraulic Power Unit (HPU

Pagina 7

Remote Human Machine Interface Operation13OperationOperation of a hydraulic power unit (HPU) from the remote human machine interface (RHMI) is the sam

Pagina 8

Remote Human Machine Interface14Operator’s PanelOperationOperator’s PanelMain ScreenThe Main screen is displayed initially when the HPU is powered up.

Pagina 9

Main ScreenRemote Human Machine Interface Operation15Name and Location DescriptionFaulted/Ready/Running/High Pressure/Alarm/Overtemp BypassIndicator.

Pagina 10 - General Safety Practices

Remote Human Machine Interface16Main ScreenOperationHigh PressurePushbutton/Indicator. Used to put the HPU in high pressure.High Pressure - gray: indi

Pagina 11 - Do not use RF

Main ScreenRemote Human Machine Interface Operation17Oil Flow (optional)Indicator/Display: Displays the total hydraulic fluid flow form all running pu

Pagina 12

Copyright information © 2011 MTS Systems Corporation. All rights reserved.Trademark information MTS and SilentFlo are registered trademarks of MTS Sys

Pagina 13 - Installation

Remote Human Machine Interface18Status ScreenOperationStatus ScreenThe Status screen is displayed by pressing the Status button on the Main screen. Th

Pagina 14

Status ScreenRemote Human Machine Interface Operation19Oil LevelIndicator. Used to indicate if the hydraulic fluid level is within acceptable limits.O

Pagina 15 - Operation

Remote Human Machine Interface20Status ScreenOperationStatusIndicator: Indicates the state of the associated module.Status - blue-green: Label.Disable

Pagina 16 - Operator’s Panel

Auto SetupRemote Human Machine Interface Operation21Auto SetupNote ROD (Run On Demand) is a purchased option.Auto Setup parameters can only be viewed

Pagina 17

Remote Human Machine Interface22Auto SetupOperationControl DescriptionsROD Flow Buffer (units)ROD Flow Buffer (units) - blue-green: Indicator used as

Pagina 18

Auto SetupRemote Human Machine Interface Operation23ROD On Delay (sec)ROD On Delay (sec) - blue-green: Indicator used as a label for the pushbutton sw

Pagina 19

Remote Human Machine Interface24Setting Up Run On Demand (ROD)OperationSetting Up Run On Demand (ROD)The ROD option automatically starts or stops pump

Pagina 20 - Status Screen

Run On Demand Detailed ExampleRemote Human Machine Interface Operation25Run On Demand Detailed ExampleRun On Demand (ROD) is a system that monitors th

Pagina 21

Remote Human Machine Interface26Run On Demand Detailed ExampleOperationAn example is shown below. In the example Module Flow is set at 30 gpm, Minimum

Pagina 22

Operating the HPU RemotelyRemote Human Machine Interface Operation27Operating the HPU RemotelyThe HPU can be operated locally using the controls on th

Pagina 23 - Auto Setup

ContentsIntroduction 3Safety 5General Safety Practices 5Installation 11Tabletop and Pedestal Mount 11Wall Mount 11Cabling 12Opera

Pagina 24 - ROD Flow Buffer (units)

Remote Human Machine Interface28Recovering From an InterlockOperation2. Add hydraulic fluid to the reservoir until the sight glass on the side of the

Pagina 25

Recovering From an InterlockRemote Human Machine Interface Operation29Watchdog Fault The HPU Fault Status on the user interface panel displays Watchdo

Pagina 26

Remote Human Machine Interface30Recovering From an InterlockOperation

Pagina 28

mMTS Systems Corporation14000 Technology DriveEden Prairie, Minnesota 55344-2290 USAToll Free Phone: 800-328-2255(within the U.S. or Canada)Phone: 952

Pagina 30 - Hyd fluid

Remote Human Machine Interface Introduction3IntroductionThe Remote Human Machine Interface (RHMI) allows you to operate a single Hydraulic Power Unit

Pagina 31

Remote Human Machine Interface4Introduction

Pagina 32

General Safety PracticesRemote Human Machine Interface Safety5SafetyGeneral Safety PracticesThe Remote Human Machine Interface (RHMI) provides remote

Pagina 33

Remote Human Machine Interface6General Safety PracticesSafetyIt is very important that you study the following safety information to ensure that your

Pagina 34

General Safety PracticesRemote Human Machine Interface Safety7Know potential crushand pinch pointsBe aware of potential crush and pinch points on your