Transducer Interface
SWIFT
®
Mini TI
Hardware Overview
25
The TI conditions the transducer signals, producing seven analog output signals
proportional to the following values:
• Longitudinal force (Fx)
• Lateral force (Fy)
• Vertical force (Fz)
• Overturning moment (Mx)
• Driving/Braking moment (My)
• Steering moment (Mz)
• Angle (θ) or Angular Velocity (ω)
Analog signals The force, moment, and angular velocity signals are output from the TI in the
form of ±10 V
1
full scale analog signals. These signals can be used by most data
acquisition systems.
The angle output is an analog voltage that is proportional to angular position. At
0° the output is 0 V. At 360°, the output is 5 V.
Coordinate
System
Oset
Matrix
1. Standard from MTS. Other full-scale output voltages can be evaluated and may be
provided at special request.