Set Process Parameters in the Group Table
MTS MultiPurpose TestWare® Creating a Practice Test Procedure
175
5. Define the second Digital Output process (Switch Fan Off).
A. In the group table, click the Digital Output (Switch Fan Off) process
icon.
B. Click the Outputs tab. Move the Fan Switch resource to the Included
list.
C. Click the Output Table tab. In our test, the cooling fan power supply is
controlled by a microswitch. This microswitch applies 110 V to the fan
when it is set high, and removes 110 V from the fan when it is set low
(or cleared). So for this process, the appropriate setting is Clear, which
turns off the fan.
D. Use the default settings on the Settings and General tabs.
6. Close the Group table and return to the main MPT Procedure Editor.
Digital Output
(Switch Fan Off)