Mts Series 793 Application Manual de usuario Pagina 241

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 576
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 240
Cyclic with ALC Process
MTS MultiPurpose TestWare® Command Processes
241
Cyclic with ALC Process
About the Cyclic with ALC Process
The Cyclic with ALC process works the same as the Cyclic process. You must
use the Cyclic with ALC process if you want to program a cyclic command and
use ALC (arbitrary end-level compensation).
Note The Cyclic with ALC process is optional. You must type a special key
code during installation to enable this process.
About ALC
compensation
Arbitrary end-level control compensation is an adaptive compensation technique
that improves the tracking accuracy of MPT.
ALC compensates for peak and valley errors by building (and continually
updating) a matrix of amplitude compensation factors.
For detailed information on the ALC compensator, see the MTS 793 Control
Software manual.
Cyclic with ALC Parameter Descriptions
General tab
General Tab
I
TEM DESCRIPTION
Name
Specifies the process name displayed on the Procedure or Group process
window.
Process Enabled
Enables the process. (Clear this box to disable the process.)
Execute Process
Specifies the number of times the process will be run.
Counter Type
Enables a process counter.
Options are None, Transient, or Fixed. Transient counters are displayed only
when the process is active. Fixed counters are displayed throughout the test.
Counter Label
Names the counter.
When you run the test, this name appears under Sequence Counters on the
MPT control panel.
Note If this box is blank, the process name is used as the counter label.