MTS MultiPurpose TestWare®
Failure Detector Process
Event Process Descriptions
384
General tab
Action
Specifies the action that occurs when the process completes.
None
The process ends without generating a message or performing an action.
Station Power
Off
The process removes hydraulic power from the station. The test can be
resumed after you reset interlocks and reapply hydraulic power to the station.
Interlock
The process triggers a hydraulic interlock and shuts down the hydraulic power
supply. The test can be resumed after you reset the interlock, reactivate
hydraulic power, and apply hydraulic power to the station.
Program
Interlock
The process triggers a program interlock. The test can be resumed after you
reset the interlock.
Program Stop
The process stops the test. This action functions the same as clicking the Stop
button on the Station Controls panel.
Program Hold
The process suspends the test until you click the Run button on the MPT
control panel. This action functions the same as clicking the Hold button on
the Station Controls panel.
Options
Tab (part 2 of 2)
I
TEM DESCRIPTION
General Tab
I
TEM DESCRIPTION
Name
Specifies the process name displayed on the Procedure or Group process
window.
Process Enabled
Enables the process. (Clear this box to disable the process.)
Execute Process
Specifies the number of times the process will be run.
Counter Type
Enables a process counter.
Options are None, Transient, or Fixed. Transient counters are displayed only
when the process is active. Fixed counters are displayed throughout the test.
Counter Label
Names the counter.
When you run the test, this name appears under Sequence Counters on the
MPT control panel.
Note If this box is blank, the process name is used as the counter label.