Using the Station Manager Application to Create
MTS Series 793 Controller Overview Operation Concepts
57
Where parameter sets
are stored
A station parameter set is not a discrete file that you can see on your desktop. It is
a discrete attribute set that is saved within a station configuration by the Station
Manager application. By default, configuration files are located at C:\MTS
793\Controllers\Controller Name (for example, FlexTest GT)\Config.
Configuration files are referenced from the Project you selected when you started
the Station Builder application. (You can change where your station
configurations are saved by changing your Project settings with the Project
Manager application.)
Recovery information
generated by
unexpected shutdowns
Series 793 controllers (except for FlexTest SE controllers) are equipped with a
Shutdown Recorder. With the Shutdown Recorder, you can capture data
surrounding unexpected shutdowns. Shutdown recorder data is stored in volatile
processor memory, or in an optional PMC flash module. If the configuration is
associated with a Project, shutdown recorder data is stored in the Project’s
Shutdown Recorder directory. You can import and analyze shutdown data with
spreadsheet applications such as Microsoft Excel.