MTS FlexTest® Models 40/60/100/200 Controller Hardware
Model 494.41 Single-Station System Board
FlexTest Controller Configurations
54
Program Interlock
Input
Input Logic
Connector J29 (D15S)
Switch Contact Closed = no program interlock
Switch Contact Open = program interlock
HPU Outputs
(Start/Low/High)
HPU Output
HPU ON Input
Connector J25 (D15P)
Output Voltage: 24 V DC at 10 mA
Trip Voltage: 0.9–5.5 V DC
Maximum Input Voltage: +26 V DC
HPU Interlock
Inputs (Low Level
and Overtemp)
Trip-point Voltage
Connector J25 (D15P)
18–23 V DC
Maximum Input Voltage: +26 V DC
Auxiliary Power
Outputs
+5 V DC
+15 V DC
-15 V DC
+24 V DC
Connector J49 (D9S)
0.75 A at 40ºC (104ºF)
0.75 A at 40ºC (104ºF)
0.75 A at 40ºC (104ºF)
0.75 A at 40ºC (104ºF)
Model 494.41 Specifications (part 2 of 3)
P
ARAMETER SPECIFICATION