Mts FlexTest Models 200 Manual de usuario Pagina 56

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 344
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 55
MTS FlexTest® Models 40/60/100/200 Controller Hardware
Model 494.41 Single-Station System Board
FlexTest Controller Configurations
56
J24 Emergency Stop Connections for the Model 494.41 System Board
The Model 494.41 System board provides two E-Stop inputs that are available on
the J24 E Stop connector (located on the rear panel of the Model 494.04
Chassis).
Cable specification To maintain EMC compliance, the J24 E-Stop cable must comply with the
following specifications:
Connector type–15-pin, type D, male EMI connector.
Backshell–EMI metallized plastic or metal.
Cable–24 AWG, four-conductor with braided shield, with the braid connected to
a metallized plastic backshell at the chassis and to ground at the emergency stop
(E-Stop) box.
Jumper plug required If connector J24 is not used, you must install a jumper plug to maintain the
integrity of the interlocks. Use jumper plug part number 039-713-201 or jumper
pins 5-7 and 8-13.
Power
100-240 VAC
50-60 Hz, 1-2 A
DA Output
J24
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
J54 Dig In
J49 Aux Pwr
J25 Hpu
Dig Out J55
Intlk J43
E-stop J29
J28 HSM
LAN 2 LAN 1
DEBUG
MOTOROLA
10/100 BASE T 10/100 BASE T
SCSI
BUSY
PIB
BUSY
PCI MEZZANINE CARD
PCI MEZZANINE CARD
494.04 Chassis
494.41 System
Board
J24 E-Stop
J24
8
13
5
7
E-Stop Box