SWIFT 20 Sensors Setting up the Low-Profile Transducer Interface
59
Setting up the Low-Profile Transducer
Interface
Important This section includes information related to the Low-Profile
Transducer Interface (TI). For SWIFT transducers designed to
operate with the newer Mini TI, there is a separate manual that
documents the Mini TI setup (MTS part number 100214316).
Overview Three different software configurations are used by the TI, depending on whether
you will be using the SWIFT sensor on the test track (spinning application) or in
the laboratory (non-spinning application). Angular transformation is required on
the test track only. If you are using angular transformation, you must define the
encoder resolution. If you are using the same transducer and TI for data
collection and simulation testing, you must change the software configuration
before the TI can be used for simulation testing.
Contents Select a Zero Method 60
Calibration File Elements 61
Zero Algorithms 62
Upload the Calibration File 64
Edit the Calibration File 66
Download the Calibration File 70