Models FlexTest® IIm/GT/SE Controller Hardware
J49 Auxiliary Power
FlexTest GT Controller Connections
140
J49 Auxiliary Power
Connector J49 Aux Pwr provides +5 V DC, ±15 V DC, and 24 V DC from the
chassis internal power supply to drive external high level conditioners, proximity
switches, solenoids, and so forth.
The outputs are fused at 0.75 A to protect the power supply from an external
short.
The fuses can be reset by shutting off power and waiting a few minutes (the
fuses automatically reset when cooled) then reapplying power.
Cable specification 9-contact type D male EMI connector
Backshell–EMI metallized plastic
Cable–shielded twisted pairs (22 AWG minimum) with drain wire(s)
connected to the metallized backshell at the chassis.
F4
F9
F7
F7
1
6
2
7
3
9
8
5
4
J49 To
External Devices
From
Chassis
-15 V DC
+24 V DC
24V
Common
+5 V DC
5V
Ground
+15 Vdc
Analog
Ground