Models FlexTest® IIm/GT/SE Controller Hardware
Sending and Receiving Signals to a Model 407
FlexTest GT Controller Connections
162
Sending and Receiving Signals to a Model 407 Controller
After cabling the Model 407 Controller, you must configure it to receive and send
signals from the FlexTest GT Controller. The tables below list typical menu
settings. Refer to the Model 407 Controller Product Information Manual for
more information.
407 Configuration Menu
P
ARAMETER SETTING
Eng Units
EOC Act
CYC Src
PROGRAM
SetPt R
150%/s (or highest)
Span R
300%/s (or highest)
Hyd Cnfg
Intlk Cnfg
MASTER
*
* Always designate one 407 in a station as a MASTER. If there are
other 407s in the same station, daisy-chain their interlocks and
designate them as DEPENDENT.
P/V Sens
Span Cnfg
1X
CMD Sel
EXT IN
Prog Out
407 Function Generator Menu
P
ARAMETER SETTING
Wvform
EXTERN
Freq
Setpnt
Span
Preset
Vista de pagina 161